background image

 

Technical Support Manual – 05/2015 Rel. 0                        

Page 12 

8. SPECIAL VISUAL SIGNALS 

The machine gives special visual signals in certain cases. The special visual signals are listed in table T8.1. 

Table T8.1: Special visual signals 

Signal 

Meaning 

Notes 

Three dots lit on one or 
both displays 

Imbalance exceeds 999 grams. 

This signal can be triggered due to: 

 

Lack of machine calibration; 

 

Incorrect measuring of the wheel dimensions; 

 

Incorrect setting of the Wheel Type; 

 

Incorrect setting of the Program Type. 

Flashing green STBY LED 

The machine is in the STAND-BY mode. 

All LEDs and displays are switched off. To exit the 
STAND-BY mode press any button  

(except for [P7] 

). 

The left (or right) display 
is flashing 

a)

 

Waiting on the user's command; 

b)

 

The Diameter or Width sensor is not 
calibrated. 

a)

 

The user's command may be the pressing a key 
to confirm or continue the procedure in 
progress or the selecting of a value or a menu 
option. 

 

9. TROUBLESHOOTING 

Table T9.1: Troubleshooting table 

Component 

Problem 

Cause 

Solution 

ENCODER DISC 

 

It does not read all the positions (0 ÷ 
255). 

 

Encoder disc dirty. 

 

Encoder disc cable 
interrupted. 

 

Encoder board burnt. 

 

Clean the encoder disc. 

 

Replace the board and then 
the cable. 

PICK-UP SIGNALS 

 

 

The values displayed are too high. 

 

The values displayed are too low. 

 

The value displayed is 0. 

The value of the signals must range 
between 70 ÷ 110 

 

Connection cable not 
welded on the pick-
up. 

 

Connection cable not 
connected to CPU. 

 

Pick-up over 
compressed. 

 

Weld the cable to the pick-up. 

 

Check the correct connection 
of the pick-up cable to the CPU. 

 

Remove the compression 
springs and make sure that the 
pick-up moves freely. 

DISPLAY 

 

One or more segments fail to switch 
on. 

 

CPU board burnt. 

 

Replace CPU board. 

KEYBOARD 

 

One or more keys failed. 

 

CPU board burnt. 

 

Replace CPU board. 

VFC 

 

The values displayed are too high. 

 

The values displayed are too low. 

 

The value displayed is 0. 

 

When knocking the machine the 
values do not change. 

The value of the VFC must range between 
40.0 ÷ 44.0. 

 

Connection cable not 
welded on the pick-
up. 

 

Connection cable not 
connected to CPU. 

 

Pick-up too 
compressed. 

 

Weld the cable to the pick-up. 

 

Check the correct connection 
of the pick-up cable to the CPU. 

 

Remove the compression 
springs and make sure that the 
pick-up moves freely. 

MACHINE 

 

The machine does not switch on. 

 

Fuse on socket.  

 

Power supply. 

 

Power board. 

 

Check and replace the fuse. 

 

Check and replace power 
supply. 

 

Check and replace power 
board. 

Table T9.2: Parameter reference values 

Parameters 

Values 

Unit of measurement 

Rotation speed 

< 80 

RPM 

Pick-up signal A 

70 ÷ 120 

CPU-C1 internal unit 

Pick-up signal B  

70 ÷ 120 

CPU-C1 internal unit 

Frequency of the converter voltage-frequency 

40.0 ÷ 45.0 

kHz 

Содержание MEC 1

Страница 1: ...EQUILIBRATRICI MEC 1 MEC 1 BAT TECHNICAL SUPPORT MANUAL UK...

Страница 2: ......

Страница 3: ...ter reset spin 8 4 PICK UP SPRING PRE CHARGE REGULATION 8 5 MACHINE CALIBRATION 9 5 1 When to carry out machine calibration 9 5 2 How to calibrate the machine for CAR SUV wheel type 9 How to exit the...

Страница 4: ...with a series of TEST programs that can be used to detect any anomaly The TEST programs are grouped inside the Test Programs menu Figure F2 1 Machine use controls Table T2 1 Settings programs and Men...

Страница 5: ...urn to SERVICE mode 4 Press keys F P9 to confirm the option 5 5 To exit the TEST Programs Menu select the Menu option Ret and press keys F P9 ENC ENCODER disc test This menu option allows you to run t...

Страница 6: ...est When you access this option the display shows the message SIG SIG as shown in figures F2 6 and F2 7 Figure F2 6 Pick up signal test message Figure F2 7 Pick up signal message To perform this test...

Страница 7: ...he VFC TEST described below If only one pick up signal differs considerably from the values indicated in table T9 2 check if I The cables of pick ups A and B have been connected to the wrong connector...

Страница 8: ...ter voltage frequency test This menu option allows you to run the converter voltage frequency test or VFC of the CPU C1 board When you access this option the display shows digits AAA BBB as shown in f...

Страница 9: ...the password by pressing the keys in the sequence indicated within 5 seconds or the machine will return to SERVICE mode a P2 b P4 c P5 d P9 The password must not be disclosed to the end user as he she...

Страница 10: ...erly the pick up must be pre charged with a spring In order to do so the spring must be compressed with a screw according to that described below 1 Manually tighten the hex screw until it stops 2 Repe...

Страница 11: ...have relevant and constant room temperature and humidity variations e g seasonal changes Recommended End user and or SERVICE Technical Support A non calibrated machine provides balancing results equa...

Страница 12: ...he CPU board 011 SPD LOW WARNING Wheel speed too low 1 Check the mains voltage 2 Check the tension of the belt and pulley 015 Damaged key code PERMANENT UNTIL TURNED OFF ERROR Damaged keys upon activa...

Страница 13: ...as not been acknowledged as valid 062 BAD TAS OPERATOR CONFIRMATION ERROR The pressed key is not permitted or an incorrect password has been entered Press the permitted key or enter the correct passwo...

Страница 14: ...high The values displayed are too low The value displayed is 0 The value of the signals must range between 70 110 Connection cable not welded on the pick up Connection cable not connected to CPU Pick...

Страница 15: ...N OF MACHINE The figures F10 1 e F10 2 show a detailed scheme of the machine Figure F10 1 Electrical wiring of the machine without internal battery MEC 1 It is possible to order the following codes 1...

Страница 16: ...t Manual 05 2015 Rel 0 Page 14 Figure F10 2 Electrical wiring of the machine with internal battery MEC 1 BAT It is possible to order the following codes 1 Cod 21201019 Power supply board 2 Cod 2120102...

Страница 17: ...anel The CPU C1 board collects the analogue signals of pick ups A and B and the sensor data encoder disc activates the electric motor processes the pick up signals and the sensor data and displays the...

Страница 18: ......

Страница 19: ...CORMACH S r l via A Pignedoli 2 42015 CORREGGIO RE ITALY Tel 39 0522 631274 Fax 39 0522 631284 e mail cormach cormachsrl com www cormachsrl com...

Отзывы: