![Corghi INTELLI-WIND Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/corghi/intelli-wind/intelli-wind_operators-manual_2667377017.webp)
17
where "x" is the number of the head whose metre count is to be monitored. If
"x" is assigned the value "all" it means that the metres wound will be monitored
for all the heads connected to the machine.
To clear the value, hold down the "ESC" key for at least 2 seconds.
To display the n° of cones wound by the heads, proceed as follows:
where "x" is the number of the head whose production is to be monitored. If "x"
is assigned the value "all" it means that the production will be monitored for all
the connected heads.
To clear the value, hold down the "ESC" key for at least 2 seconds.
Set up of language and units of measurement
To display and change the language and the units of measurement, proceed as
follows:
The language can be "English" or "Italian", while the units of measurement can
be "metric" or "imperial".
INSTALLATION
The man/machine interface consists of a central control unit with a display and
keyboard.
The unit runs on a 220 V supply, the 3-core cable transmits the programmed
speed to the inverters, and the 4-core cable communicates with the various
peripheral boards installed on the machine modules.
The 2 core cable is connected to the key-switch on the electrical control unit
which enables the machine settings, and the flat cable terminating in the 9-pin
D-connector is used for updating or downloading the software from a P.C.
On power-up, the display illuminates completely and then displays the number
of connected boards, followed by the number of heads that have been
recognised. If the number of heads displayed does not match the number of
heads installed, refer to the troubleshooting section. The values displayed and
the state of the indicator lights along the machine depend on how the machine
was switched off; in fact the metre counter stores all the parameters in memory.
MENUS
X OUTPUT DATA
CONES
SETTINGS
LANGUAGE
UNITS