Core NEO9S AG Скачать руководство пользователя страница 3

  Charge the battery in ambient temperature range of 0

o

C and 45

o

C.  For best results 

charge in an environment between 10

o

C and 35

o

C.  Charging in conditions outside the 

aforementioned ranges may inhibit the pack from reaching maximum charge capacity. 

 

2.  Discharging the battery:  

• Maximum continuous discharge for the is 12A(144W) with a 10second peak discharge rate of 
16A(192W)  

• The LCD automatically switches between 3 different phases; Normal RT(based on default 30wh 
draw), Remaining RT(based on actual draw, when in use), and Remaining Charge Time(when 
connected to a charger).  

• Press the side LED button for 1 second to activate the backlight feature.  

• During operation, the battery samples the current entering or exiting the battery in 7 second 
intervals. During the charging process, the charge current fluctuates, causing the Charge Time 
readings to vary.  

 

LED Indication Guide: 

 

Overtime the RunTime LCD and power gauge’s accuracy is dependent upon a full charge and discharge. 
At least once every 2 months the battery should be fully cycled(discharged and echarged) so the battery 
can relearn the capacity of the battery.  

 

Battery Storage: 

In the event the battery pack won’t be used for an extended period of time, store the battery pack at 40% 
charged in an environment between 10

o

C and 35

o

C.  Every two months the battery pack should be fully 

cycled to reduce the change of self discharge and capacity loss. 

 
 
 
 
 

 

 

   

 

 

 

   

 