![Core NEO9S AG Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/core/neo9s-ag/neo9s-ag_instructional-manual_2666910003.webp)
•
Charge the battery in ambient temperature range of 0
o
C and 45
o
C. For best results
charge in an environment between 10
o
C and 35
o
C. Charging in conditions outside the
aforementioned ranges may inhibit the pack from reaching maximum charge capacity.
2. Discharging the battery:
• Maximum continuous discharge for the is 12A(144W) with a 10second peak discharge rate of
16A(192W)
• The LCD automatically switches between 3 different phases; Normal RT(based on default 30wh
draw), Remaining RT(based on actual draw, when in use), and Remaining Charge Time(when
connected to a charger).
• Press the side LED button for 1 second to activate the backlight feature.
• During operation, the battery samples the current entering or exiting the battery in 7 second
intervals. During the charging process, the charge current fluctuates, causing the Charge Time
readings to vary.
LED Indication Guide:
Overtime the RunTime LCD and power gauge’s accuracy is dependent upon a full charge and discharge.
At least once every 2 months the battery should be fully cycled(discharged and echarged) so the battery
can relearn the capacity of the battery.
Battery Storage:
In the event the battery pack won’t be used for an extended period of time, store the battery pack at 40%
charged in an environment between 10
o
C and 35
o
C. Every two months the battery pack should be fully
cycled to reduce the change of self discharge and capacity loss.
Содержание NEO9S AG
Страница 1: ...NEO9S AG Battery Pack Instructional Manual...