D.
Installation
It is highly recommended to choose DC adapter for using
AirStat®
Model 7110 Pulsed AC Ionizing Bar unless in-tool
ionization and remote control application.
The wiring installation must be tested and qualified before
the power is applied to the ionizing bar. See the following
wiring instruction for Model 7110 Pulsed AC Ionizing Bar.
Prior to connecting ionizing bar to power supply, test each
cable for opens, short and polarity. Do not connect the
cable until the voltage and cable combinations are verified.
FMS
–
Wiring Cable
No.
Color
Item
Description
1
Orange/White DC 24V +
DC Power Daisy Chain
2
Orange
DC 24V +
DC Power Daisy Chain
3
Green/White
Run/Stop
Monitoring System
4
Blue
Clean
Monitoring System
5
Blue/White
HV Fail
Monitoring System
6
Green
Alarm COM
Monitoring System Ground
7
Brown/White
GND
Power Supply Ground
8
Brown
GND
Power Supply Ground
After the wiring has been tested, connect the cable and
apply power to the ionizer. Performed the adjustment
procedure to determine the final settings and if necessary,
adjust individual parameters.