Page 8
All equipment MUST be secured
(bolted and tightened) to a solid, level
surface, using all of the anchoring
holes provided, to stabilize and
eliminate rocking or tipping over. Shim
any mounting surface that does not
rest thoroughly on the floor using flat
washers, DO NOT force the foot to
contact the ground with anchors.
Fasteners must have a minimum of 500 lbs. tensile capacity, be a bolt of grade 2 or better and be installed per
the bolt manufacturer’s specifications.
Due to the wide variety of flooring on which equipment may be anchored or installed and differences in
applicable local building codes, Core Health & Fitness is not responsible for any damage to the flooring that
may result due to anchoring or installing equipment to the floor and for compliance with local building codes.
Only licensed contractors or certified installers should be used to insure proper anchoring, installation, and
compliance with local building code.
Required Tools:
• Metric Allen Key Set
• Loctite Blue
1
• Torque Wrench
• Metric Open-Ended Wrench Set
• Large Adjustable Crescent Wrench
THREAD LOCKER APPLICATION:
Clean all threads and holes, apply no more than 3-4 drops per bolt.
Thru Holes
Blind Holes
PACKAGING REMOVAL:
Unit is heavy and requires two people for assembly.
Carefully remove all packaging materials that wrap the equipment.
DO NOT USE A KNIFE OR BOX CUTTER AS YOU MAY DAMAGE THE EQUIPMENT.
At this time remove any sub-components from the pallet and set aside for later assembly. Once all packaging
has been removed, lay all parts out in a clean open area to prepare for assembly. Should any component not
be present or if you have any operational questions, please refer to
SUPPORT & SERVICE
After assembly, a complete visual inspection, and test of the features and functions of the assembled unit must
be made prior to use.
ASSEMBLY
Metric Steel Bolts Torque Specifications
Bolt Size
Thread Pitch
Torque, N-m (lbs-ft)
6mm
1.25
10 to13.5 (8 to10)
8mm
1.25
25.5 to 28.5 (19 to 21)
10mm
1.75
55.5 to 58 (41 to 43)
12mm
1.25
61 to 65 (45 to 48)
• Torque all hardware to values as specified above, unless noted otherwise.
• See procedure of this manual for fastener sizing information; for reference only.
Note: All torque values are in N-m unless otherwise stated.