Corby PLATINUM 7500 SERIES Скачать руководство пользователя страница 2

P

LATINUM 

S

ERIES 

K

EYPAD 

I

NSTRUCTIONS 

-

 

P

AGE 

2

Keypad Connections

B

ENCH 

T

ESTING THE 

K

EYPAD

This bench test assumes the keypad is unprogrammed.  If it

has been progr amm ed, follow  the 

Factory Reset Function

 found in

the 

Programming 

section.)

Step 1.

Enter default master code [1-2-3-4], followed by the
pound sign [#].  The Green LED will light up and the door
relay will energize for 5 seconds.

Step 2.

Enter default user code [5-6-7-8-9-0], followed by the
pound sign [#].  The Green LED will light up and the door
relay will energize for 5 seconds.

Step 3. Go to the next section, 

Installing & Wiring the Keypad

.

If th e mast er code o r user c ode is i ncorr ectly  entered,  the Red

LED will li ght up  for 3 s econds . Re-ent er the m aster  or user  code.

If the master code or user code still does not work, reset the

keypad  to fac tory  defaul t usi ng the 

Factory Reset Function

 found

in th e 

Programming 

section.

I

NSTALLING AND 

W

IRING THE 

K

EYPAD

Step 1.

After choosing the mounting location for the keypad, drill
the mounting holes using the enclosed template or mount
to an electrical back box or low voltage wiring device if
appropriate.  

 DO NOT insert the Security Plugs into

the screw holes at this time. THE SECURITY PLUGS
ARE DESIGNED TO BE TAMPER RESISTANT AND
MUST BE DRILLED OUT TO BE REM OVED.

Step 2.

Using the diagram at right, connect
the power and door relay wires to the
keypad .  See

 Application Examples

Section

 for ideas on how to connect

the keypad in your application.  

If

you use this product to operate a
DC door strike, magnetic lock,
relay or any device that has a coil
(inductive load) that is powered
from a DC source, you M UST
install a varistor in parallel across
the coil terminals.  

The varistor

provi ded wit h thi s keypa d is des igned
to be used with a 12 VDC door lock. 
If you are using a 24 VDC lock, do
not use the varistor that came with
your keypad.  The varistor should
prevent the high voltage spike that
occur s when t he lock  coil  is de-
energized.

  If you do not use a varistor, you will have

erratic operations and eventually damage the keypad
and any other electronic device in the system.

Step 3.

Turn on the power supply. The following will happen:

i)

The keypad s buzzer will beep briefly.

ii)

The keypad s Red LED will illuminate briefly.

iii)

The keypad is r eady fo r use.

 

 Go to the next section,

Programming the Keypad

.

P

ROGRAMMING THE 

K

EYPAD

 

All programming is performed using the Keypad. Here are

some tips to help you program your keypad:

WHEN PROGRAMMING , YOU MUST WAIT W HILE THE
RED LED IS ON SOLID.  CONTINUE ENTERING DATA
WHEN THE RED LED BEGINS FLASHING.

IM PORTANT ! 

 CHANGE THE FACTORY-SET MASTER

CODE 

(1234) 

USING FUNCTION 2 AFTER PROGRAMMING

THE KEYPAD.  It may be easier to do all the necessary
programming before you change the master code.  Be sure to
keep a copy of the new master code in a secure and
accessible location.

IM PORTANT !  

BEFORE YOU INSTALL THE KEYPAD, MAKE

SURE YOU ERASE THE FACTORY-SET USER CODE
(567890) USING FUNCTION 4.

Entering Program Mode

To enter program mode, enter the asterisk twice (**), then the

Master Code, and then the asterisk twice(**) again.

Example:

** 1 2 3 4 **

The Red LED will turn on solid for three seconds, and then will

flash slow, indicating that you are in program mode.  You must
wait until the Red LED flashes to continue, as the keypad is
processing information and will not accept new input.  Once the
Red LED is flashing, you may enter any of the four program
options, or you may enter the pound sign (#) to exit program
mode.  If you do not enter a program option within 15 seconds, the

keypad will automatically exit program mode. 
If this happens, you will need to re-enter the
Master Code to continue programming.

Program the Relay for Momentary Time

Enter 1 and the Red LED will light for

three sec onds a nd then  flas h fast .  Then ent er
the elapsed time, in seconds, for the door to
be unlocked.  You must use two digits, i.e.,
enter a number between 01 and 99.  Enter the
pound  sign ( #) to confi rm t his ent ry. The Red
LED will light for three seconds (to
acknowledge the entry), then the Red LED will
begin to flash slow.  You are now back at the
main program m enu.

Examples:

To set relay to 15 seconds, enter:  1 15 #

Program the Relay for Latching

 Enter 1  and th e Red LED wi ll li ght f or three secon ds and  then

flash fast.  Then enter two zeros (00) to set the relay to latching
mod e.  Enter  the pou nd sig n (#) t o conf irm  this  entry. The Red
LED will li ght f or three secon ds (t o ackn owledg e the entr y) th en
the Red LED will begin to flash slow.  You are now back at the
main program m enu.

Examples:

To set relay to latching, enter:

1 00 #

Change the Master Code

Enter 2  and th e Red LED wi ll li ght f or three secon ds and  then

flas h fast .  Enter  the Master Cod e slot  numb er (00) , and t hen enter
the pound sign (#).  The Red LED will light for three seconds (to
allow time to acknowledge the entry) and then it will resume
flashing. Enter your new Master Code, followed by the pound sign
(#).  The Master Code must be between 4 and 8 digits, and must
be num bers on ly (*  and # ar e not va lid c ode num bers) . The Red

Отзывы: