8) Operational Check
a. Insert key into cylinder and rotate (Fig. 20a).
b. There should be no friction against lock case, wire harness or
any other obstructions.
c. Check that the key retracts the latch.
d. The key should rotate freely.
e. Try the inside lever; ensure it retracts latch.
f. Use a valid credential* set up with the
Lock Configuration Tool
to
unlock outside lever and retract latch.
Refer to
Network and Lock Configuration
Tool
user manual (
WFMN1
) for information on
how to configure and program locks.
When lock is fully installed, perform the following steps:
*
Twenty (20) seconds after lock initialization
(single beep with lock motor actuation).
Note: The credential should approach the inscription
on the reader as indicated (Fig. 20b) to ensure
that the credential is read properly.
Do not wave credential.
Fig. 20b