![Corbin Russwin ED5200N Series Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/corbin-russwin/ed5200n-series/ed5200n-series_installation-instructions-manual_2666783018.webp)
18
Copyright © 2018 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
ED5200N & ED5600N Series
Exit Devices For 9100/9M100
IN120 Series Trim
7) IN120 Installation Instructions (Continued)
1. Install Outside Reader - (Continued)
Gasket*
Mounting Plate
*Gasket is required for outdoor installations.
If installing with gasket; separate gasket from mounting plate to feed cables
through holes as indicated (Fig. 15b).
Once cables/connectors are fed through, reattach gasket to mounting plate.
Lock body Harness
Ground Lug
DPS
Reader Harness
e. When all connections have been made, tuck ferrite bead
and excess cable into wire hole on inside of door.
f. Secure the mounting assembly while ensuring proper
alignment of outside reader and tighten the (2) through-bolts
on the inside of the door to secure the reader (Fig. 15b).
g. Secure ground lug with #6-32 machine screw (Fig.15c).
d. Next feed the cables/connectors through the inside mounting assembly (and gasket if required*).
NOTE: Cable lengths exaggerated for illustrative purposes.
Inside of Door
Through -
bolt
Through -
bolt
Fig. 15c
Fig. 15b