L(mm) W(mm) H(mm) D(mm) A(mm) B(mm) X(mm) F(mm)
590
520
55
51
560+4
+1
490+4
+1
50 mini 3 mini
Under any circumstances, make sure the ceramic cooker hob is well ventilated and the air inlet and outlet
are not blocked. Ensure the ceramic cooker hob is in good work state. As shown below
Note: The safety distance between the hotplate and the cupboard above the hotplate should be at
least 760mm.
A(mm) B(mm)
C(mm)
D
E
760
50 mini 20 mini Air intake Air exit 5mm
Min.3mm
F
A
X
X
X
B
L
H
D
W
X
Min.30mm
A
B
E
C
D
8.1 Selection of installation equipment
Cut out the work surface according to the sizes shown in the drawing.
For the purpose of installation and use, a minimum of 5 cm space shall be preserved around the hole.
Be sure the thickness of the work surface is at least 30mm. Please select heat-resistant and insulated
work surface material (Wood and similar fibrous or hygroscopic material shall not be used as work surface
material unless impregnated)
to avoid the electrical shock and larger deformation caused by the heat
radiation from the hotplate. As shown below:
Note: The safety distance between the sides of the hob and the inner surfaces
of
the worktop
should be at least 3mm.
8. Installation
16
Содержание CCVM400