Section 363-719-102
June 2, 1997
Revision 01
Page 16
PairGain Engineering - Plant Series
PG-Flex FCS-719
Table 12. Alarm Termination
Posts
Contact
Post
NO*
Contact
Post
COM*
Contact
Post
NC*
FUNCTION†
SHELF_ID
1
2
3
Shelf ID indicates a major or minor shelf alarm is active.
MAJ_AUD
4
5
6
Indicates a major alarm. The alarm can be silenced using the ACO
button. Connect this relay to the major alarm audible indicator of
the CO alarm system.
MAJ_VIS
7
8
9
Indicates a major alarm. This alarm cannot be disabled.
Connect this relay to the major alarm visual indicator of the
CO alarm system.
MIN_AUD
10
11
12
Indicates a minor alarm. The alarm can be silenced using the ACO
button. Connect this relay to the minor alarm audible indicator of
the CO alarm system.
MIN_VIS
13
14
15
Indicates a minor alarm. This alarm cannot be disabled.
Connect this relay to the minor alarm visual indicator of the
CO alarm system.
*
For the relay contacts, NO is normally opened, NC is normally closed, and COM is common.
† All relays provide form “C” contacts.