Section 150-388-124
Revision 01
Page 8
TABLE 1. HLU-388, LIST 2D SYSTEM OPTIONS
Mode
Selection
Description
EQL
0*
Sets the equalizer to DSX-1 for 0 to 132 feet.
133
Sets the equalizer to DSX-1 for 133 to 265 feet.
266
Sets the equalizer to DSX-1 for 266 to 398 feet.
399
Sets the equalizer to DSX-1 for 399 to 532 feet.
533
Sets the equalizer to DSX-1 for 533 to 655 feet.
LPBK
DIS
Configures the HiGain system to ignore the (2 in 5) in-band Smart-Jack loopback command.
ENA*
Enables the HiGain system to recognize the (2 in 5) in-band Smart-Jack loopback command.
SPLB
GNLB*
Configures the HiGain system to respond to the generic (3/4/5/6 in 7) in-band loopback
codes.
A1LB and
A2LB
Configures the HiGain system to respond to the Teltrend addressable repeater in-band
loopback codes.
A3LB
Configures the HiGain system to respond to the Wescom addressable repeater in-band
loopback codes.
A4LB
Configures the HiGain system to respond to the Wescom Mod 1 addressable repeater
in-band loopback codes.
A5LB
Configures the HiGain system to respond to the Teltrend Mod 1 addressable repeater in-band
loopback codes.
PWRF
DIS
Disables powering to the HRU-412 and doubler.
ENA*
Enables powering to the HRU-412 and doubler.
ZBTS
ON
Tells the HiGain system that the ESF frame is operating in its Zero Byte Time Slot Interface
(ZBTSI) mode.
OFF*
Tells the HiGain system that the ESF frame is operating in its normal non-ZBTSI mode.
ESAL
17
Flashes the red Status LED when 17 Errored Seconds (ES) (17 HDSL cyclic redundancy
check (CRC) errors on either HDSL loop or a total of 17 BPVs) occur within a 24-hour
period.
170
Flashes the red Status LED when 170 ES (170 HDSL CRC errors on either HDSL loop or a
total of 170 BPVs) occur within a 24-hour period.
NONE*
Prevents generation of a minor alarm due to excessive errored seconds.
LBTO
NONE
Disables automatic time-out cancellation of all loopbacks.
20
Sets automatic cancellation of all loopbacks to 20 minutes after initiation.
60*
Sets automatic cancellation of all loopbacks to 60 minutes after initiation.
120
Sets automatic cancellation of all loopbacks to 120 minutes after initiation.
ALM
DIS*
This generic HiGain ALM option is not supported by the HLU-388, List 2D. Its setting has
no effect on the units operation.
ENA
Note:
An asterisk (*) indicates HLU-388, List 2D factory (default) settings.
Table continued on next page