Revision 01
March 31, 1998
150-412-181-01
4
PairGain Engineering - Plant Series
HRU-412 List 8A
S
PECIFICATIONS
HDSL
Line Code
784 kbps 2B1Q full duplex
Output
+13 dB + 0.5 dB at 135 ohms
Line Impedance
135 ohms
Startup Time
15 seconds (typical), 60 seconds (maximum)
Maximum Provisioning Loss
35 dB at 196 kHz, 135 ohms
Line Clock Rate
Internal Stratum 4 clock
Power Consumption
5 Watts (typical), 7 Watts (maximum)
Electrical Protection
Secondary surge and power cross protection on all DS1 and HDSL ports
Environmental
Operating Temperature
- 40° C to + 65° C
Humidity
5 to 95% (non-condensing)
Mounting
Single wide 400 Mechanics type shelf
DS1
One-way Delay
< 220 microseconds per span
Line Impedance
100 ohms
Pulse Output
0 dB (RLEV = 0), -15 dB (RLEV = 15)
Input Level
> -22.5 dB
Line Rate
1.544 Mbps + 200 bps
Содержание 150-1103-81
Страница 41: ......