Notices of installation
Unpacking lnspection
•
Open the box and check air conditioner in area with good ventilation (open the door
and window) and without ignition source.
Note:
Operators are required to wear anti-static devices.
•
It is necessary to check by professional whether there is refrigerant leakage before
opening the box of outdoor machine; stop installing the air conditioner if leakage is
found.
•
The fire prevention equipment and anti-static precautions shall be prepared well before
checking. Then check the refrigerant pipeline to see if there is any collision traces, and
whether the outlook is good.
Safety Principles for lnstalling Air Conditioner
•
Fire prevention device shall be prepared before installation.
•
Keep installing site ventilated.(open the door and window)
•
lgnition source,smoking and calling is not allowed to exist in area where R32 refrigerant
located.
•
Anti-static precautions in necessary for installing air conditioner, e. g. wear pure cotton
clothes and gloves.
•
Keep leak detector in working state during the installation.
•
lf R32 refrigerant leakage occurs during the installation, you shall immediately detect
the concentration in indoor environment until it reaches a safe level. lf refrigerant leakage
affects the performance of the air conditioner, please immediately stop the operation,
and the air conditioner must be vacuumed firstly and be returned to the maintenance
station for processing.
•
Keep electric appliance, power switch, plug, socket, high temperature heat source and
high static away from the area underneath sidelines of the indoor unit.
•
The air conditioner shall be installed in an accessible location to installation and
maintenance, without obstacles that may block air inlets or outlets of indoor/outdoor
units, and shall keep away from heat source, inflammable or explosive conditions.
•
When installing or repairing the air conditioner and the connecting line is not long
enough, the entire connecting line shall be replaced with the connecting line of the
original specification; extension is not allowed.
•
Use new connection pipe, unless re-flaring the pipe.