background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

   

 

 

 

 

   

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

   

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

   

   

 

   

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

   

 

     

 

 

 

 

 

   

 

 

 

 

 

   

 

 

 

   

   

 

 

   

 

 

 

   

 

 

 

 

 

 

   

   

 

 

 

 

   

   

   

   

 

 

   

 

 

   

 

 

 

 

 

 

 

 

 

   

 

 

 

   

   

   

 

 

 

 

 

 

 

 

 

 

 

     

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

  

 

 

 

  

 

 

  

  

  

  

    

 

 

 

 

 

   

 

   

 

 

 

 

 

 

 

 

 

 

 

 

4c. Slipfitter Mount (FIG. 4c)

• The integral slipfitter can be mounted on 2" (2 3/8"

O.D.) pipe. Set screws and a thru bolt are provided to
clamp it securely to the tenon. Thru bolt will require a
drilled hole thru the arm or tenon. Use the slipfitter as a
pattern to drill the thru hole. Secure electrical leads
from the drill path. Remove slipfitter and clean burrs on
tenon from drilled hole. Reinstall the slipfitter. Remove
the cover plate from slipfitter and bring leads into 
compartment. Pull power supply leads and the ground
lead into the bottom half of the slipfitter. Be sure the
pivot retainer bolt is tightened securely after aiming is
accomplished. Tighten all mounting bolts per 

FIG. 4c

.

4d. Trunnion Mount (FIG. 4d)

• If the unit is provided with a trunnion which can be

mounted directly on a flat surface (Adapters are 
available for installation on building fronts, poles,
crossarms, pipes, etc.) 14-3 SO cable is 
recommended for making electrical connection. 
The fixture is provided with a grommnet and a strain 
relief (approximately 9/16" diameter). To maintain the
seal, screws in the strain relief must be retightened
whenever the seal is disturbed.

5. Socket Setting Adjustment—Type II or Type III Only

(FIG. 5)

• Socket is normally factory set to provide IES Type II light

distribution pattern. To obtain IES Type III distribution,
proceed as follows

(FIG. 5).

• Loosen the two (2) hex head clamping screws 

sufficiently for the socket to clear the indexing screws.

• Move socket bracket so that the indexing screws 

engage appropriate indexing holes. See table 

(FIG. 5)

for socket position and resulting light pattern.

These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible contingency 
during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please contact your nearest 
representative.

Tribute

Sheet 3 of 4

1/7/08

IMI-685

INSTALLATION INSTRUCTIONS

IMPORTANT 

: READ CAREFULLY BEFORE INSTALLING FIXTURE. 

NOTE: Specifications and dimensions subject to change without notice

Visit our web site at www.cooperlighting.com

Customer First Center  1121 Highway 74 South  Peachtree City, GA  30269  770.486.4800  FAX  770.486.4801    

ADH070937

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

     

 

 

 

   

 

 

 

 

 

 

 

 

 

FIG. 4c 

(Slipfitter Mount)

Pivot Retainer Bolt

Torque to 40-50

foot-pounds

3/8-16 x 4”

Hex Head Thru Bolt

with lock nut.

Set screw 

Torque to 15-20

foot-pounds

2" [51mm]

3" [77mm]

5 3/8" [137mm]

3 1/2"

[89mm]

FIG. 4d

 (Trunnion Mount)

Mounting

Holes

3/8-16 Bolt

(Torque to 120-140

inch-pounds)

FIG. 5

Clamping

Screw (2)

Socket
Mount

Indexing

Hole

Indexing

Screw (2)

Light Pattern 

Socket Index Position

IES Type 

250W Clear HPS Lamp 

All other Clear 

 

(5 3/4” LCL)* 

HID Lamps (5” LCL)*

II A  B
III C  D

NOTE: *

 Light Center Length.