4
COOPER LIGHTING SOLUTIONS
IB521009EN
Installation instructions
Installation Instructions - Archeon Medium
6. Install cosmetic cover if applicable over arm and tighten
screws.
7. Pull wires through center holes on nut plate and pole.
8. Make electrical connection as established in the
wiring instructions. Refer to the standard installation
instructions.
Straight Arm (Figure 8.)
1. Insert nut plate into pole and align insert holes with the
mounting holes in the pole.
2. For round poles only - Install round plate adapter with
round side facing pole (Figure 8). Align holes top and
bottom.
3. Insert bolts through the washer, arm, adapter (if
applicable) and pole top and bottom holes. Screw into
nut plate.
4. Torque bolts using 3/8” Allen socket/wrench to 35~40
ft-lbs.
5. Pull wires through center hole in nut plate, pole,
adapter and arm.
6. Make electrical connection as established in the
wiring instructions. Refer to the standard installation
instructions.
Photocontrol - If Equipped (Figure 9.)
ote:
N
If your luminaire is equipped with a photocontrol
receptacle, see IB525002EN Photocontrol
Receptacle Supplement to identify your photocontrol
and follow the instructions on the diagram and all
applicable notes.
Maintenance
ote:
N
A regular maintenance schedule should be
followed to retain optimal light output and thermal
performance. Optical lens cleaning should be
performed with a clean dry cloth to remove any dust
or other contaminants. Additional cleaning can be
performed with using a non-abrasive polycarbonate
cleaner. Remove any dirt, leaves or other foreign
debris from the housing.
Electrical Wires
Round Pole
Adapter
Nuts
Washer
Backup
Plate
Arm
Adjustment
Slot for North
Electrical Wires
Round Pole
Adapter
Threaded Rods
Nuts
Washer
Backup
Plate
Arm
Cover Plate
Figure 7.
Figure 8.
Figure 9.