Metalux • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801
08/26/2008 2:48:16 PM
Specifications and Dimensions subject to change without notice.
ADF080359
PHOTOMETRICS
ORDERING INFORMATION
SHIPPING INFORMATION
2AC
C o e ffi c i e n t s o f U t i l i z a t i o n
Effective floor cavity reflectance
20%
rc
80%
70%
50%
30%
10%
0%
rw
70 50 30 10
70 50 30 10
50 30 10
50 30 10
50 30 10
0
RCR
0
1
2
3
4
5
6
7
8
9
10
L u m i n a n c e Da t a
Average
Average
Average
Angle
0-Deg
45-Deg
90-Deg
in Deg
cd/sm
cd/sm
cd/sm
45
2186
2425
2628
55
2115
2513
2830
65
1996
2651
2902
75
1743
2524
2574
85
1331
1939
1857
Z o n a l L u m e n S u m m a r y
Zone
Lumens
%Lamp
%Fixture
0-30
0-40
0-60
0-90
0-180
||
C a n d l e p owe r
Angle
Along
II
45°
Across
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
2AC-232-UNV-EB81
Electronic Ballast
(2) F32T8/835 Lamps
3100 Lumens each
Spacing criterion:
(II) 1.3 x mounting
height, ( ) 1.5 x
mounting height
Efficiency 84.9%
Test Report:
2AC-232-UNV-
EB81.IES
LER = FL80 LPW
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $2.90
1613
1613
1613
1605
1610
1616
1585
1594
1604
1550
1568
1585
1501
1530
1557
1439
1482
1520
1365
1424
1476
1279
1357
1424
1183
1281
1365
1079
1197
1297
966
1106
1220
847
1006
1133
722
898
1021
589
782
856
452
634
663
315
456
465
187
280
277
81
118
113
0
0
0
101 101 101 101
99 99 99 99
94 94 94
90
90 90
87 87 87
85
92 87 83 80
89 85 82 79
82 79 76
78 76 74
75 73 72
70
83 75 69 64
81 74 68 63
71 66 62
68 64 60
65 62 59
57
75 66 58 53
73 64 57 52
62 56 51
59 54 50
57 53 49
47
69 58 50 44
66 57 49 44
54 48 43
52 47 42
51 46
42
40
63 51 43 38
61 50 43 37
49 42
37
47 41 36
45 40 36
34
58 46 38 33
56 45 38 32
44 37 32
42 36 32
41 36 31
30
54 42 34 29
52 41 34 28
40 33 28
38 32 28
37 32 28
26
50 38 30 25
48 37 30 25
36 30 25
35 29 25
34 29 25
23
46 35 28 23
45 34 27 23
33 27 22
32 26 22
31 26 22
21
44 32 25 20
42 32 25 20
31 25
20
30 24 20
29 24 20
19
1279
20.6
24.3
2127
34.3
40.4
3942
63.6
74.9
5266
84.9
100.0
5266
84.9
100.0
S A M P L E N U M B E R : 2 AC - 2 3 2 - U N V- L 8 8 4 1 - E B 8 2 - U
Voltage
(1)
UNV=Universal
Voltage 120-277
Options
GL=Single Element Fuse
GM=Double Element Fuse
Flex=Flex installed
EL=Emergency Installed
Packaging
U=Unit Pack
PALC=Job Pack,
in carton
Shielding
Blank=Frosted Acrylic
SQP=Lens with Square
Pattern Insert
RDP=Lens with Round
Pattern Insert
NOTES:
(1)
Products also available in non-US voltages and frequencies for international markets.
For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice.
Consult your Cooper Lighting Representative for availability and ordering information.
Lamps
L8835=T8 Lamp, 17W
and 32W, 3500K
L8841=T8 Lamp, 17W
and 32W, 4100K
L8835HL=T8 Lamp,
32W, 3500K, 3100
Lumens
L8841HL=T8 Lamp,
32W, 4100K, 3100
Lumens
Ballast Type
EB8 =T8 Electronic Instant Start.
Total Harmonic Distortion < 10%
EB8 /PLUS=T8 Electronic Instant Start.
High Ballast Factor >1.13. Total
Harmonic Distortion < 20%
ER8 =T8 Electronic Program Rapid Start.
Total Harmonic Distortion < 10%
HPT8 Ballast
Ballast
HB8 L=T8 Electronic Instant Start. Low Ballast Factor .77
HB8 =T8 Electronic Instant Start. Ballast Factor .88
HB8 N=T8 Electronic Instant Start. Normal Ballast Factor 1.0
HB8 H=T8 Electronic Instant Start. High Ballast Factor 1.15-1.2
HR8 L=T8 Electronic Program Start. Low Ballast Factor .77
HR8 =T8 Electronic Program Start. Ballast Factor .88
HR8 H=T8 Electronic Program Start. High Ballast Factor 1.15-1.2
No. of Ballast
1 or 2
No. of
Ballast
1 or 2
No. of Ballast
1 or 2
Number of Lamps
(Not included)
2=2 Lamp
Wattage (Length)
32=32W T8 (48")
Series
AC=Accord Series
Width
2=2' Width
Rating
Blank=
Standard
NY=New York
Rated
ATW-SW4=
Chicago
Rated
Type
A=Air (optional)
=T8 Electronic Program Start Step Dimming. Ballast Factor .88
HR8_DI M
.
s
b
l
8
2
2
3
2
-
C
A
2
Catalog No.
Wt.