17
English
1. GAS FILLING
1. Use original Weller Pyropen gas.
2. Be sure that the switch ring is in “OFF“ position.
3. Hold the Pyropen Jr. handle with tip pointing downward, refill nozzel in
upright position. Insert nozzel of gas container and press down.
4. As soon as the Pyropen Jr. is filed, gas will flow over.
5. Hold the tool firmly and see the window to read LP gas volume inside.
2. HOW TO USE SOLDERING TIP AND HEAT TIP
1. Push up switch ring marked (A) and turn to right. Gas will start to flow.
Set mark °between “ON“-1.
2. Push knurled cap marked (B) fully upward. Be sure not to cover air take-
in hole (marked C), as flame will leak out ignition vent and catalyst will not
react (see illustration below).
3. While holding the knurled cap upward, ignite ignition vent by using a
match or lighter. When the inside of ignition vent turns red, release the knur-
led ring. It will return to its original position and generate heat.
4. Adjust tip temperature by moving the switch ring (1-3).
5. To turn off, slide the switch ring to “OFF“ position.
6. For any job with hot air replace soldering tip by hot blow tip.
IGNITION VENT
KNURLED NUT
SWITCH RING
PK Elektronik Vertriebs GmbH, E-Mail: [email protected], Internet: www.pkelektronik.com