background image

PDF Only

Customer Satisfaction Team

Available to answer questions regarding Cooper
Bussmann products & services Monday-Friday,
8:00 a.m. – 4:30 p.m. for all US time zones.

s

 Toll-free phone: 855-287-7626 (855-BUSSMANN)

s

Toll-free fax: 800-544-2570

s

E-mail: [email protected]

Emergency and After-Hours Orders

Next flight out or will call shipment for time-critical needs.
Customers pay only standard product price, rush freight
charges, & modest emergency service fee. Place these
orders through the Customer Satisfaction Team during
regular business hours.  For after-hours, contact:

s

Phone: 314-995-1342

– the Enhanced, Online Cooper Customer Center

Provides real time product availability, net pricing, order
status & shipment tracking across six Cooper divisions:
B-line, Bussmann, Crouse-Hinds, Lighting, Power
Systems & Wiring Devices. Available at:

s

www.cooperc3.com

s

877-995-5955 for log-in assistance

Application Engineering

Technical assistance is available to all customers.
Staffed by degreed engineers, this application support
is available Monday-Friday, 8:00 a.m. – 5:00 p.m. CT
Contact:

s

Phone: 636-527-1270

s

Fax: 636-527-1607

s

E-mail: [email protected]

s

Live Chat: www.cooperbussmann.com

Online Resources

Visit www.cooperbussmann.com for the following
resources:

s

Product search & cross-reference

s

Product & technical materials

s

Solutions centers for information on topical issues

including arc-flash, selective coordination &
short-circuit current rating

s

Technical tools, like our arc-flash calculator

s

Where to purchase Cooper Bussmann product

Services

Cooper Bussmann Services team provides engineering
expertise in electrical system reviews, electrical safety
training & component testing for Agency compliance.
Contact:

s

Phone: 636-207-3294

s

E-mail: [email protected]

C

3

Customer Assistance

Your Authorized Cooper Bussmann Distributor is:

C o o p e r B u s s m a n n
S t . L o u i s , M O 6 3 1 7 8
8 5 5 . 2 8 7 . 7 6 2 6   ( 8 5 5 -

B U S S M A N N

)

w w w. c o o p e r b u s s m a n n . c o m

Contact:

©2011 Cooper Bussmann

www.cooperbussmann.com

8

www.cooperbussmann.com/BussmannWirelessResources

3A1578Rev1.9

Содержание BU-905U-L-R

Страница 1: ...Cooper Bussmann BU 905U L R Receiver Quick Start Guide Version 1 9 3A1578Rev1 9 Read and Retain for Future Reference ...

Страница 2: ...air of transmitter and receiver units The basic steps for using your unit are 1 Connect the antenna power supply and transducer signals using the instructions in this document Power supply and transducer connection is described in the section Unit components and connections Antenna connection is described in the section Antenna installation For more information see the BU 905U L Installation Manua...

Страница 3: ... comply with Electrical Safety Regulations this module must be installed in an Electrical AND Fire enclosure This enclosure may be a single or multiple enclosures Access to the module is to be made by a Service Person only In order to comply with Electrical Safety Standards when connecting SELV AND voltages which are greater than SELV 30Vac or 60Vdc together then Relay Output 2 must NOT be used in...

Страница 4: ...n you press the RSSI push button the unit shows the signal strength by lighting the LEDs Button Pressed from the bottom to the top Signal strength is the strength of the last message received that was addressed to this station LED Signal Strength LED Signal Strength D1 More than 85 dBm RX More than 100 dBm D2 More than 90 dBm CF More than 105 dBm D3 More than 95 dBm PG Always on during RSSI test O...

Страница 5: ...L R receiver flashes all LEDs at medium flash i e 1 6Hz NOTE If the LEDs do not flash you must repeat steps 1 and 2 until the LEDs flash before continuing 4 Release the RSSI push button within 5 seconds 5 Within a further 60 seconds press and hold the RSSI push button for 5 seconds until the LEDs stop flashing and then release 6 The BU 905U L R receiver lights all LEDs for 2 seconds before returni...

Страница 6: ...warranty Exposure to RF energy is an important safety consideration The FCC has adopted a safety standard for human exposure to radio frequency electromagnetic energy emitted by FCC regulated equipment as a result of its actions in Docket 93 62 and OET Bulletin 65 Edition 97 01 FCC Notice When Used in USA BU 905U L Wireless I O Module Part Additional information 15 This device has been tested and ...

Страница 7: ...dditional Information Digital Outputs 3 Voltage free contacts rated at 250Vac 1A 30Vdc 1A 2 for digital inputs and 1 for setpoint Status Outputs 2 Separate System OK and communication failure output Analog Output 1 16 bit resolution 0 1 accuracy single ended source output Power Supply 1 9 30Vdc 0 25 Amp CSA certified Class 2 power supply For use in Class I Div 2 hazardous locations the power suppl...

Страница 8: ... assistance is available to all customers Staffed by degreed engineers this application support is available Monday Friday 8 00 a m 5 00 p m CT Contact s Phone 636 527 1270 s Fax 636 527 1607 s E mail fusetech cooperindustries com s Live Chat www cooperbussmann com Online Resources Visit www cooperbussmann com for the following resources s Product search cross reference s Product technical materia...

Отзывы: