background image

6

www.cooperbussmann.com/BussmannWirelessResources

Cooper Bussmann BU-905U-L-R Receiver Quick Start Guide

Linking Your Transmitter and Receiver Units

You must reset the transmitter unit to factory defaults (to disable encryption) before linking the transmitter and receiver units.
For more information, see the 

BU-905U-L-T Transmitter Quick Start Guide

.

NOTE:

You must complete the linking process in 60 seconds.

To link the transmitter and receiver units:

1. Press and hold down the RSSI Pushbutton on the receiver.

2. Power on the receiver while holding down the RSSI Pushbutton

3. Release the RSSI Pushbutton as soon as the Receiver LEDS flash (within 5 seconds of powering the receiver).

4. The receiver will flash all LEDs for a maximum 60 seconds while it tries to link to the transmitter.

5. Power on the transmitter. The transmitter sends a special “Link” message to allow the receiver to recognize the transmitter.

6. When the units link, the receiver lights all LEDs for 2 seconds before returning to normal operation.

NOTE:

If the receiver LEDs continue flashing within the 60 seconds, the units are not linked and you should retry the linking process by powering

the transmitter off and on again. If you exceed the 60 seconds, you must restart the linking process from step 1.

7. You can now bench test your configuration before deploying.

Safety information

Thank you for selecting the BU-905U-L-R receiver for your telemetry needs. We trust it will give you many years of valuable service. To ensure
your BU-905U-L-R receiver enjoys a long life, double-check ALL your connections with the user’s manual before powering on the unit.

WARNING:

Incorrect termination of supply wires may cause internal damage and will void warranty.

Exposure to RF energy is an important safety consideration. The FCC has adopted a safety standard for human exposure to radio frequency 
electromagnetic energy emitted by FCC regulated equipment as a result of its actions in Docket 93-62 and OET Bulletin 65 Edition 97-01.

FCC Notice When Used in USA: BU-905U-L Wireless I/O Module

Part

Additional information

15

This device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part15 of the FCC 
rules (Code of Federal Regulations 47CFR Part 15). Operation is subject to the condition that this device does not cause 
harmful interference.

90

This device has been type accepted for operation by the FCC in accordance with Part90 of the FCC rules (47CFR Part 90).
See the label on the unit for the specific FCC ID and any other certification designations.

Industry Canada: BU-905U-L Wireless I/O Module

RSS-119 - This device has been type accepted for operation by Industry Canada in accordance with RSS-119 of the Industry Canada rules. See
the label on the unit for the specific Industry Canada certification number and any other certification designations.

NOTE:

Any changes or modifications not expressly approved by Cooper Bussmann P/L could void the user’s authority to operate this equipment.

To operate this equipment legally the user must obtain a radio-operating license from the government agency. This is done so the government can
coordinate radio users in order to minimize interference.

Safety Information - FCC Notice

This device complies with Part 15.247 of the FCC Rules. Operation is subject to the following two conditions:

• This device may not cause harmful interference; and

• This device must accept any interference received, including interference that may cause undesired operation

NOTE:

This equipment is suitable for use in Class 1 Division 2 groups A, B and C or non-hazardous locations only.

3A1578Rev1.9

Содержание BU-905U-L-R

Страница 1: ...Cooper Bussmann BU 905U L R Receiver Quick Start Guide Version 1 9 3A1578Rev1 9 Read and Retain for Future Reference ...

Страница 2: ...air of transmitter and receiver units The basic steps for using your unit are 1 Connect the antenna power supply and transducer signals using the instructions in this document Power supply and transducer connection is described in the section Unit components and connections Antenna connection is described in the section Antenna installation For more information see the BU 905U L Installation Manua...

Страница 3: ... comply with Electrical Safety Regulations this module must be installed in an Electrical AND Fire enclosure This enclosure may be a single or multiple enclosures Access to the module is to be made by a Service Person only In order to comply with Electrical Safety Standards when connecting SELV AND voltages which are greater than SELV 30Vac or 60Vdc together then Relay Output 2 must NOT be used in...

Страница 4: ...n you press the RSSI push button the unit shows the signal strength by lighting the LEDs Button Pressed from the bottom to the top Signal strength is the strength of the last message received that was addressed to this station LED Signal Strength LED Signal Strength D1 More than 85 dBm RX More than 100 dBm D2 More than 90 dBm CF More than 105 dBm D3 More than 95 dBm PG Always on during RSSI test O...

Страница 5: ...L R receiver flashes all LEDs at medium flash i e 1 6Hz NOTE If the LEDs do not flash you must repeat steps 1 and 2 until the LEDs flash before continuing 4 Release the RSSI push button within 5 seconds 5 Within a further 60 seconds press and hold the RSSI push button for 5 seconds until the LEDs stop flashing and then release 6 The BU 905U L R receiver lights all LEDs for 2 seconds before returni...

Страница 6: ...warranty Exposure to RF energy is an important safety consideration The FCC has adopted a safety standard for human exposure to radio frequency electromagnetic energy emitted by FCC regulated equipment as a result of its actions in Docket 93 62 and OET Bulletin 65 Edition 97 01 FCC Notice When Used in USA BU 905U L Wireless I O Module Part Additional information 15 This device has been tested and ...

Страница 7: ...dditional Information Digital Outputs 3 Voltage free contacts rated at 250Vac 1A 30Vdc 1A 2 for digital inputs and 1 for setpoint Status Outputs 2 Separate System OK and communication failure output Analog Output 1 16 bit resolution 0 1 accuracy single ended source output Power Supply 1 9 30Vdc 0 25 Amp CSA certified Class 2 power supply For use in Class I Div 2 hazardous locations the power suppl...

Страница 8: ... assistance is available to all customers Staffed by degreed engineers this application support is available Monday Friday 8 00 a m 5 00 p m CT Contact s Phone 636 527 1270 s Fax 636 527 1607 s E mail fusetech cooperindustries com s Live Chat www cooperbussmann com Online Resources Visit www cooperbussmann com for the following resources s Product search cross reference s Product technical materia...

Отзывы: