Description
• Designed to IEC 127-4
• Surface Mount fuse, time lag
• Solder Immersion Compatible
• Overcurrent protection of systems up to 250VAC
Approvals
• Designed to IEC 127, Sheet 4 (approval pending)
Environmental Data
• Termination Strength: IEC 127-4 Clause 8.3.2
• Soldered Joints: IEC 127-1 Clause 8.5
• Solderability: IEC 127-4 Clause 8.6.2 subjected to Test
Td of IEC-68-2-58 with the following conditions; Aging:
none. Immersion conditions: exceeds IEC 127-4.
Depth of immersion: entire metal surface. Flux type:
non-activated. Solder type: 60% tin and 40% lead
according to IEC 68-2-20, Appendix B.
• Resistance to Soldering Heat: IEC 127-4 Clause 8.7
subjected to Test Td of IEC 68-2-58 with the following
conditions; Aging: none. Immersion conditions: 260°C
± 5°C, 10 seconds ± 1 sec. Depth of immersion:
10mm. Flux type: activated. Solder type: 60% tin and
40% lead
• Insulation Resistance: IEC 127-4, Clause 9.3.3
(resistance
≥
0.1Mohms)
Ordering
• Specify product code and packaging code
Soldering Method
• Wave Immersion: 260°C, 10 sec max.
• Infrared: 260°C, 30 sec max.
3.07
±
0.15
(0.121
±
0.006)
2.77
±
0.15
3.07
±
0.15
(0.109
±
0.006)
(0.121
±
0.006)
2.77
±
0.15
(0.109
±
0.006)
3.30
(0.130)
4.38
(0.172)
6.79
(0.267)
1.4
±
0.25
1.4
±
0.25
(0.055
±
0.010)
(0.055
±
0.010)
2.77
±
0.15
(0.109
±
0.006)
3.07
±
0.15
(0.121
±
0.006)
10.29
±
0.20
(0.405
±
0.008)
1.4
±
0.25
1.4
±
0.25
(0.055
±
0.010)
(0.055
±
0.010)
2.77
±
0.15
(0.109
±
0.006)
3.07
±
0.15
(0.121
±
0.006)
10.29
±
0.20
(0.405
±
0.008)
Land Pattern
Dimensions
mm
⁄
(inches)
Drawing Not to Scale
Top View
Side View
End View
Brick
™
Fuses
1025T Series
Time Lag, Low Breaking Capacity
ELECTRICAL CHARACTERISTICS
% of Amp Rating
Opening Time
125%
1 Hours Minimum
200%
2 Minutes Maximum
200%
1 Second Minimum
1000%
0.01 -- 0.1 Seconds
SPECIFICATIONS
Voltage
Interrupting
DC Cold
Typical
Typical
Max.
Marking
Product Code
Rating
Rating*
Resistance** (ohms)
Melting
Voltage
Voltage
Code
AC DC
250VAC 125VDC
min.
typ.
max.
I
2
t†
Drop‡
Drop‡
1025T250mA
250V 125V
100A 50A
TBD TBD TBD
TBD
TBD
800
Dt
1025T500mA
250V 125V
100A 50A
TBD TBD TBD
TBD
TBD
600
Ft
1025T800mA
250V 125V
100A 50A
TBD TBD TBD
TBD
TBD
400
KKt
1025T1A
250V 125V
100A 50A
TBD TBD TBD
TBD
TBD
300
Ht
1025T1.6A
250V 125V
100A 50A
0.064 0.074 0.083
12.26
155 mV
300
MMt
1025T2A
250V 125V
100A 50A
TBD TBD TBD
TBD
TBD
300
Nt
1025T2.5A
250V 125V
100A 50A
0.045 0.048 0.051
32.91
TBD
300
Ot
1025T3.15A
250V 125V
100A 50A
0.030 0.034 0.038
54.98
184 mV
300
Qt
1025T4A
250V 125V
100A 50A
TBD TBD TBD
TBD
TBD
300
St
1025T5A
250V 125V
100A 50A
TBD TBD TBD
TBD
TBD
300
Tt
1025T6.3A
250V 125V
100A 50A
TBD TBD TBD
TBD
TBD
300
OOt
* AC Interrupting Rating (Measured at designated voltage, greater than 95% power factor); DC Interrupting Rating (Measured at designated voltage, time constant of
the calibrated circuit is less than 1 millisecond, battery source)
** DC Cold Resistance (Measured at
≤
10% of rated current)
† Typical Melting I
2
t (Measured with a battery bank at rated DC voltage, 10x-rated current, not to exceed IR, time constant of calibrated circuit less than 50 microseconds)
‡ Typical Voltage Drop (Measured at rated current after temperature stabilizes)
• Device designed to carry rated current for four hours minimum. An operating current of 80% or less of rated current is recommended, with further derating required at
elevated ambient temperatures.