Description
• The first and most reliable surface mount telecom circuit
protector designed to protect against power cross faults
and comply with all surge requirements.
• Allows compliance with telecom regulatory standards
including Bellcore GR 1089, UL 1950/60950, and FCC part
68. Application circuit testing is recommended.
• Eliminates the need for a current limiting resistor.
• Protects against overcurrent conditions found in telecom tip
and ring applications.
• RoHS Compliant version available (-R option)
* If the device does not open at 250% within 120 seconds, increase
current to 300% of amp rating. Device must open in 10 seconds max.
Agency Information
• UL Recognition Card: JDYX2/E19180
• CSA Component Certification Record and Class No.:
053787C000, 1422 30
Environmental Data
• Life Test: MIL-STD-202, Method 108A, Test Condition D
• Load Humidity: MIL-STD-202, Method 103B
• Moisture Resistance: MIL-STD-202, Method 106E
• Thermal Shock: MIL-STD-202, Method 107D, air-to-air
• Case Resistance: EIA/IS-722
• Resistance to Dissolution of Metallization:
ANSI J-STD-002, Test D
• Mechanical Shock: MIL-STD-202, Method 213B, Test
Condition A
• High Frequency Vibration: MIL-STD-202, Method 204D,
Test Condition D
• Resistance to Solvents: MIL-STD-202, Method 215A
Soldering Method
• Wave Immersion: 260°C, 3 sec max.
• Infrared: 240°C, 30 sec max.
5.2
3.7
(0.204)
(0.145)
4.0
(0.157)
12.6
(0.496)
Land Pattern
Dimensions
mm
⁄
(inches)
ELECTRICAL CHARACTERISTICS
% of Amp Rating
Opening Time
100%
4 Hours Minimum
250%
1 Second Minimum
250%
4-10 Seconds Typical
250%*
120 Seconds Maximum
300%
10 Seconds Maximum
ELECTRICAL AND POWER CROSS SPECIFICATIONS
Product
Voltage
Interrupting
DC Cold
Typical
Maximum
Typical
Alpha Code
Code
Rating
Rating*
Resistance** (ohms)
Melting
Total
Voltage
Marking
AC
250VAC 600VAC
min.
typ.
max.
I
2
t†
Clearing
Drop‡
1st Code 2nd Code
TCP500mA
250 V
50 A 40 A
0.420 0.530 0.640
1.3 A
2
s
100 A
2
s
471mV
F
TCP1.25A
250 V
50 A 60 A
0.070 0.090 0.110
22.2 A
2
s
100 A
2
s
150mV
J
TCP2A
250 V
50 A 60 A
0.050 0.075 0.100
30 A
2
s
100 A
2
s
205mV
N
* AC Interrupting Rating (Measured at designated voltage, 100% power factor)
** DC Cold Resistance (Measured at 10% of rated current)
*** On RoHS Compliant Version (-R option)
† Typical Melting I
2
t (Measured with a battery bank at 60V DC, 10x-rated current, time constant of calibrated circuit less than 50 microseconds)
‡ Typical Voltage Drop (Measured at rated current after temperature stabilizes)
R***
LIGHTNING SURGE SPECIFICATIONS
Surge Specification
Surge
Repetitions
Waveform
Current (A)
Voltage (V)
Performance
(µSec.)
Requirement
TCP 500mA tested
FCC 47 Part 68
Longitudinal Type B
2
5x320
37.5
N/A
Fuse cannot open
FCC 47 Part 68
Metallic Type A
2
10x560
100
800
Fuse must open safely
Surge out
25
10x160
65
N/A
Fuse cannot open
TCP 1.25A and TCP2A tested
FCC 47 Part 68
Longitudinal Type A
2
10x160
100 per fuse
1500
Fuse cannot open
FCC 47 Part 68
Metallic Type B
2
10x560
100
800
Fuse cannot open
Bellcore GR-1089-CORE
First Level Lightning
50
10x1000
100
1000
Fuse cannot open
Bellcore GR-1089-CORE
First Level Lightning
50
2x10
500
2500
Fuse cannot open
Surge out
1
10x160
160
N/A
Fuse cannot open
Surge out
1
10x560
115
N/A
Fuse cannot open
TCP
™
Series
Telecom Circuit Protector