Air Source Heat Pump Water Heater
12
6 Installation
6.1 Notices for Installation
●
Important Notices
1) Installation of the unit must be done by qualified personnel according to local layout rules and this
Instruction.
2) Before installation, please contact with local maintenance center. Malfunction resulted from non-
authorized department is not easy to handle.
3) When removing the unit to the other place, please firstly contact with the local maintenance center.
4) Suggest choose the shower that rating flow is 6~7L/min, in order to ensure comfort of using.
●
Basic Requirements for Installation Location
Installation at the following places may cause malfunction of the water heater. Please contact installation
and service agency if the installation at such places cannot be avoided.
1) A place with heat source, steam and inflammable gases.
2) A place with high frequency facilities, such as radio equipment, electric welder or medical equipment;
3) A region with saline-sodic soil near the sea;
4) A place full of machine oil;
5) A place with sulphide gases (such as sulphur spring);
6) An environment with special conditions
●
Selection of Installation Location of Main Unit
1) A place where noise and airflow generated by air exhaust do not affect the neighbors, animals and
plants.
2) Ensure good ventilation of main unit.
3) No obstacles near the main unit obstructing the air intake and air exhaust of the unit.
4) The installation position shall be able to withstand the weight and vibration of the main unit.
5) Choose a place far away the direct sunshine or strong wind.
6) The main unit shall be in conformity with the requirements of installation diagram, and ensure
sufficient space for service and maintenance.
7) The length of circulating water connection pipe is within 5m.
8) Please select the place out of the children's reach.
9) Select the place which do not influence the communal path way and the appearance of the city.
6.2 Installation of Main Unit of Water Heater
1) The requirement for installation of main unit is the same as that for outdoor unit of AC .It can be
installed on the wall, rooftop, balcony or floor. Air outlet should be kept away from the upwind direction.
2) The distance between main unit and each of the walls around or other shelters shall not be too small.
The following requirements shall be met.(Unit: mm)
Air outlet
>
500
>
1000
>
500
>
1200