Refrigerant R410A is non-flammable, non-toxic, and odorless, and may produce toxic gases when exposed to
open flame. Since this refrigerant gas is heavier than air, it may result in lack of oxygen, thereby leading to
breathing difficulties when the area near the ground is filled with this gas. If that's the case, please turn off the
main switch immediately, cut off the power supply, and open the doors and windows for ventilation. Put out any
open flame, and contact your service dealer. Performing leak detection and gas tightness test with oxygen,
acetylene or other flammable and toxic gases may cause explosion, so nitrogen is recommended for this test.

͓

The standards for safe refrigerant leakage in construction and system operation are determined based on local
regulations or standards.

͓

Use ELB with medium or higher sensing speed (ELB with an operating time of 0.1 seconds or less), or
electric shock or fire may arise.

͓

For installation, the refrigerant piping must be firmly connected before the operation of compressor. For repair,

the refrigerant piping must be moved, handled and removed after the stop of compressor.

͓

Please don't short-circuit the protective device (e.g., the pressure switch, etc.) during operation, since this
may cause fire or explosion.

͓

͓

͓

͓

͓

͓

͓

͓

͓

Do not use any sprays such as insecticide, lacquer, hair spray or other flammable gases within approximately 
one 

3.3ft.(

1

m)

 from the system.

If the earth leakage breaker (ELB) is frequently activated, please stop the system and contact your local dealer 
or customer services.
Make sure the ground wire is securely connected. The improper grounding of machine may lead to electrical 
failure. Please don't connect the ground wire to gas pipes, tap water pipes, lightning rods or phone ground 
wires.
Make sure there are no flammable materials around during brazing operation. Please wear leather gloves to 
prevent frostbite when filling refrigerant.
Prevent rats or other small animals damaging the wiring and electrical components. Bitten unprotected parts 
may cause a fire.
Firmly fix the connection wires. The external force of terminal may result in looseness of terminal that may 
cause a fire.
Make sure the air conditioner is installed with enough strength of fixation; otherwise, the air conditioner may 
fall or topple over, which may bring about machine damage or personal injury.
Please follow the installation instructions and related regulations and standards for electrical construction; 
otherwise, electrical failure or fire may occur due to inadequate capacity or inconsistent specifications. 
Never fail to use specified wiring and select correct wiring, since failure to do so may cause electrical failure or 
fire.
Please make sure the outdoor unit is not covered with snow or ice before use.

͓

Please don't perform installation works such as refrigerant piping connection, drain pipe connection, and 

wiring connection. Violations may result in system leakage, electrical failure or fire. In the case of fire, please 
turn off the power immediately; please don't touch electrical parts with the hands, or electric shock may arise. 
Do not pour water into the indoor or outdoor unit. This machine is an electric product that may develop 
serious electric failure when exposed to water.
Do not open the service cover of indoor or outdoor units without turning OFF the main power supply; 
otherwise, this may bring about serious safety accident.
Do not touch or adjust safety devices inside the indoor or outdoor units. If they are touched or readjusted, 
serious accident may arise.

DANGER

:$51,1*

 

Ȼ

͓

The A-weighted emission sound pressure level at workstations, where this exceeds 70 dB(A).

͓

 

This appliance can be used by children aged from 8 years and above and persons with reduced physical, 

sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or 
instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not 
play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.

Содержание CHV-09MCC4W

Страница 1: ...NDITIONER PLEASE READ AND UNDERSTAND THIS MANUAL BEFORE USING THE AIR CONDITIONER KEEP THIS MANUAL FOR FUTURE REFERENCE 4 WAY CASSETTE TYPE ORIGINAL INSTRUCTIONS CHV 09SCC4W CHV 12SCC4W CHV 15SCC4W CH...

Страница 2: ......

Страница 3: ...at pump air conditioner within this range Do not have the air outlet directly faced towards animals or plants since this may bring about an adverse effect thereon The installation and service engineer...

Страница 4: ...imals damaging the wiring and electrical components Bitten unprotected parts may cause a fire Firmly fix the connection wires The external force of terminal may result in looseness of terminal that ma...

Страница 5: ...responsible for any consequence arising from the modification to equipment without our written consent 03257 17 127 Correct Disposal of this product This marking indicates that this product should not...

Страница 6: ......

Страница 7: ...Materials 5 2 Piping Connection 8 Test Run 9 Protection Control Devices 10 Field Operation Electrical Wiring 7 1 General Check 7 2 Wiring 7 3 Field Wire Size for Power Source Line 2 4 5 6 Drain Pipe...

Страница 8: ......

Страница 9: ...e etc may occur 87 21 Be careful not to cause damage to insulation materials of the unit surface when it s lifted 7RROV QVWUXPHQWV IRU QVWDOODWLRQ QVWDOODWLRQ RI QGRRU 8QLW Transport the product as cl...

Страница 10: ...unit where the electromagnetic wave is directly radiated to the electrical box remote control cable or remote control B Install the indoor unit and components as far as practical or at least 9 8ft 3m...

Страница 11: ...asher Suspension Bolt Suspension Bracket Water Pan Fig 4 6 Mounting Nuts and Washers Suspension Bolt Field Supplied Nut Field Supplied Insulating Washer Accessory Bracket for Fixing Indoor Unit Washer...

Страница 12: ...ctors between the indoor unit and air panel Flange Surface Indoor Unit Bottom View Ceiling Indoor Unit Surface of Suspended Ceiling Suspension Bolt Surface of Ceiling Indoor Unit Bolt M6 Pattern Board...

Страница 13: ...nance Manual for outdoor unit Excessive and inadequate refrigerant is a leading cause of system anomaly Please inject the right amount of refrigerant Pipe Size mm Tightening Torque ft N m 10 3 13 3 14...

Страница 14: ...e drain pipe connection is shown 2 Prepare a polyvinyl chloride pipe with a 32mm outer diameter 3 Fasten the tubing to the drain hose with the adhesive agent and the factory supplied clamp The drain p...

Страница 15: ...p the wires with adhesive tape or other materials and plug the wiring connection hole with seal material to protect the product from any condensate water or insects The electrical box entrance hole sh...

Страница 16: ...Amps A MOP Max Overcurrent Protective Device A kW Fan Motor Rated Output kW FLA Full Load Amps A Connecting Hole for Power Supply Wiring Connecting Hole for Communication Cables and Wire Controller Ca...

Страница 17: ...ot operate the system until the electrical leakage is found and repaired B Check to ensure the stop valves of outdoor unit are fully opened and then start the system C Check to ensure the switch on ma...

Страница 18: ...ls 1 and 2 of TB2 the PCB fuse will be blown In such a case it s essential to correct the wiring and then to set switch No 1 to ON position Note Symbol indicates the location of DIP switch The positio...

Страница 19: ......

Страница 20: ...3DFNLQJ LVW Details Remarks 1 Set 1 pc pc pcs pc 1 pc 6 pcs 2 pcs 1 pc 1 pc 1 pc Indoor Unit Operation Installation Maintenance Manual Pipe Clamp 1 pc 08 20 V01...

Отзывы: