4. Put wiring cover back and then tighten the screw.
5. Close the panel.
Installation of indoor unit
Note:
●
All wires of indoor unit and outdoor unit should be connected by a professional.
for a new one. Avoid extending the wire by yourself.
installation.
● For the air conditioner without plug, an
air switch must be installed in the line.
The air switch should be all-pole parting and the contact parting distance should
be more than 3mm.
power connection
wire
cable-cross
hole
2. Make the power connection wire go
through the cable-cross hole at the back
of indoor unit and then pull it out from
the front side.
2
7
N(1)
2
4
5
blue
violet orange
black
yellow-
green
Outdoor unit connection
07 09 12
、
18K
3. Remove the wire clip; connect the power connection wire to the wiring terminal
according to the color; tighten the screw and then fix the power connection wire
with wire clip.
Note: the wiring board is for reference only, please refer to the actual one.
N(1)
2
black
yellow-
green
Outdoor unit connection
24K Heat pump type:
3
4
5
blue
brown violet orange
Heat pump type:
N(1)
yellow-
green
Outdoor unit connection
28K Heat pump type:
2
3
blue black brown
Содержание CH-S07GKP8
Страница 9: ...7 Buttons on remote controller...