DC Inverter U-match Series Duct Type Unit
2
Before installing the air conditioner, please read the instruction manual.
Before repairing the air conditioner, please read the instruction manual.
The figures in this manual may be different with the material objects,
please refer to the material objects for reference.
PROHIBITED
(1) The air conditioner should be grounded to avoid electric shock. Do not connect
the ground wire to gas pipe, water pipe, lightning arrester or telephone wire.
(2) The appliance shall be stored in a well-ventilated area where the room size
corresponds to the room area as specified for operation.
(3) The appliance shall be stored in a room without continuously operating open
flames (for example an operating gas appliance) and ignition sources (for
example an operating electric heater).
(4) According to federal/state/local laws and regulations, all packages and
transportation materials, including nails, metal or wooden parts, and plastic
packing material, must be treated in a safe way.
WARNING
(1) Please install according to this instruction manual. Installation must be
performed in accordance with the requirement of NEC and CEC by authorized
personnel only.
(2) Any person who is involved with working on or breaking into a refrigerant circuit
should hold a current valid certificate from an industry-accredited assessment
authority, which authorises their competence to handle refrigerants safely in
accordance with an industry recognised assessment specification.
(3) Servicing shall only be performed as recommended by the equipment
manufacturer. Maintenance and repair requiring the assistance of other skilled
personnel shall be carried out under the supervision of the person competent in
the use of flammable refrigerants.
(4) The appliance shall be installed in accordance with national wiring regulations.
(5) The fixed wires connecting to the appliance must be configured with all-pole
disconnection device under voltage grade III according to wiring rules.