background image

6. OPERATION OF THE UNIT

6

Pressing this button again sets the device to an average evaporation 
rate — the second concentric circle lights up at the top of the display.
To set the maximum evaporation rate, press the button a third time. 
Pressing it again will return you to the minimum level of evaporation. The 
button “Setting the humidity level in the manual mode” works only when 
the Manual mode is selected.

1. Air humidifier - 1 pc.
2. Brush for cleaning membranes - 1pc.
3. Operation manual - 1 pc.
4. Filter - 1 pc.

5. SCOPE OF DELIVERY

• 

Automatic mode / Child mode (12):

It is a button for selecting one of four mutually exclusive modes of 
operation. Press this button to switch the instrument to Automatic 
mode. The evaporation rate in this mode is presented in Table 2. 
Repeated pressing of this button takes the device to Children’s mode 
with a preset humidity of 55%, recommended for young children. If you 
want to return to Automatic mode, click this button again.

Humidity

Evaporation rate

before 40%

Maximum

40%-60%

 

Average

over 60%

Minimum

Table 2

• 

Night mode (11):

It is a button for selecting one of four mutually exclusive modes of 
operation. Press this button to reset the instrument.

went to the SMART night mode. If within 5 seconds after pressing this 
button you do not perform any actions, the device switches to Night 
mode, the display of the device turns off, and only the corresponding 
indication remains on. 

In this mode, the timer will automatically turn on, 

set to 8 hours. The evaporation rate in this mode is shown in Table 2. If 
any button is pressed in the SMART Night mode, except “On / Off”, the 
Hygrometer will show the current humidity in the room, then after 5 
seconds the Display will turn off again. Double pressing of the button 
“Manual mode / Evaporation rate” or “Automatic mode / Child mode” 
will activate another mode. Pressing the “On / Off” button will turn off the 
instrument. When you turn on the settings again, you will need to set it 
again.

• 

Ionization  (10)

This button includes an ionizer that compensates for the lack of 
negatively charged ions (anions) in the air. 

Anions strengthen the nervous and circulatory systems, improve lung 
function and provide protection against respiratory diseases (such as 
pneumonia and asthma).

• 

Automatic  shutdown  in  case  of  insufficient  water  level  (5):

This indication lights up when water is running out in the device. To 
avoid overheating of the ultrasonic membrane, the device shuts off 
automatically.

1. Holding the handle, remove the water tank from the device (see fig. 1)
2. Turn the water tank upside down and unscrew the tank lid by turning it

counterclockwise.

NOTE:

The filter cartridge is attached to the water tank cap. If you

are not going to use the filter, you should remove it by

turning it counterclockwise.

3. Pour clean water into the tank. For this model it is recommended to

use demineralized water. Do not over-fill the tank! After filling, close the 

tank cap, turning it clockwise.
4. Place the tank back into the device.

NOTE:

Do not pour water into the base of the device - it may fall 

into the hole for overflow, and the surface under the device 

becomes wet.

An overflow hole is provided in order to eliminate the risk of 

water entering the electronic components of the device 

through an air-blowing hole (Fig.2).

Содержание CH-3040

Страница 1: ......

Страница 2: ......

Страница 3: ...Model Ultrasonic air humidifier CH 3040 Instruction manual Outlook of devices aslo colour scores can be revised without any special advance notices...

Страница 4: ...results in drying of mucous membranes which in its turn is the reason for decrease in immunity headache lip cracking sandpaper in the eyes it also enables infection spreading and respiratory tract di...

Страница 5: ...t operate the unit without water in the basin Do not insert foreign objects into the device Do not touch the transducer or the lower water basin when the unit is operating Do not scratch the transduce...

Страница 6: ...em blows out this water into the dry air where they evaporate to give the required humidity The clearly visible smooth and even fog can be seen out of the unit FRONT PANEL AND LED DISPLAY 4 Fig 1 Devi...

Страница 7: ...mode 11 Night mode 12 Kid Auto mode 13 Manual Mode Evaporation Rate On Off Button 9 If the device is plugged in the On Off indication on the device display automatically lights up To turn on the devi...

Страница 8: ...any button is pressed in the SMART Night mode except On Off the Hygrometer will show the current humidity in the room then after 5 seconds the Display will turn off again Double pressing of the butto...

Страница 9: ...isms bacteria inside the pan That will lead to unpleasant smells and violation of hygienic norms Use as much as possible pure water Water often contains calcium salts rust particles and other chemical...

Страница 10: ...8 8 9 10 11 13 13 14 15 16 1 2 3 4 5 6 7 8 9 Cooper Hunter Cooper Hunter 1 40 60 220 240 50...

Страница 11: ...9 2 30 C...

Страница 12: ...1 2 3 4 5 10 1 2 6 8 7 9 10 6 7 8 9 10 3 1 220 240 50 4 0 25 37 IP20 II 175x290x285 2 72 2 30 40 300 20 5 20 4...

Страница 13: ...11 1 2 3 4 5 6 7 1 12 8 30 5 40 80 9 10 11 12 13 9 8 3...

Страница 14: ...12 OL 40 10 OL 5 7 1 12 1 12 5 00 8 8 6 13 12 2 55 40 40 60 60 2 11 SMART 5...

Страница 15: ...https climagroup com ua brands ch 13 1 1 2 1 3 1 4 1 1 1 2 8 2 SMART 5 10 5 4 3 4 2 1 2 6 5...

Страница 16: ...14 1 2 3 4 1 5 10 2 5 2 3 4 1 2 1 2 3 30 5 40 80 30 2 7...

Страница 17: ...15 4 3 4 80 8 12...

Страница 18: ...https climagroup com ua brands ch 16 9 12...

Страница 19: ......

Страница 20: ......

Отзывы: