Revised: 13/10/2015
PPPrintew
- 4 -
4 of 19
- 4 -
Printed: 14/10/2015
P
RODUCT
F
EATURES
MODEL-Hermitage,
Chateau, Chateau II
GAS TYPE
NATURAL
L.P.G
Manufacturer
MODEL TYPE
GAS INPUT
HIGH
LOW
HEAT OUTPUT
HIGH
LOW
Efficiency
Injector Size
Manifold Pressure
High
Low
A.G.A Approval
No. to Code AS 4553-
2008
Freestanding
Inbuilt
33 MJ/h
23 MJ/h
7.6 kW
5.2 kW
83 %
2.8 mm
1.0 kPa
0.48 KPa
AGA 6165 G
Freestanding
Inbuilt
33 MJ/h
23 MJ/h
7.6 kW
5.2 kW
83 %
1.6 mm
2.6 kPa
1.3 KPa
AGA 6165 G
Shamic Sheetmetal
(Aust.) Pty.Ltd
.
PO BOX 8,
KILSYTH,
VIC. 3136
To be installed by an
authorized person in
accordance with
installation instructions
provided with the
appliance.
Electrical
Conform to AS3100
240V 50 Hz 120 Watts Max
Air Pressure Switch
Aria 380 series (5471)
Cut in Pressure
45 Pa
Cut out Pressure
40 Pa
Electrical Connection
Standard Flex. 2 Mt. 3 Pin Plug
Coonara “Chateau” Series 2 Inbuilt Gas Log Space Heater
33 Mj/h Gas Input Natural Gas and LPG.
7.19 kW Output.
Energy rating
4.6
Stars
Electronic ignition.
Two heat settings.
External combustion air intake - prevents de-oxygenation of room air.
Delayed start room fan - prevents cold air being circulated at start-up.
Delayed stop room fan - aids cool down of unit when switched off.
Power flue.
Integrated safety features.
The Coonara “Chateau” Series 2 Inbuilt model is approved by the Australian Gas Association to AS 4553-
2008 for gas space heating appliances.
AGA Approval No. 6165