Procedure:
•
Turn off the appliance.
•
Disconnect appliance from the electrical supply
•
Empty the tank (see par. 4.12) until the water level is lower than the place where the electric
resistance element is installed.
•
Unscrew the and remove the plastic cap.
•
Disconnect the cable from the electric resistance element.
•
Remove and replace the electric resistance element.
•
Check that there are no water leaks from the fitting.
•
Re-connect electrical cable.
•
Replace
the plastic cap.
•
Fill the tank.
•
Restore the electrical supply to appliance.
•
Restart the heat pump system.
5.11 Outside cleaning
For the cleaning of the outer shell only use soapy solutions, avoiding abrasive products containing
organic thinners (alcohol, benzine, etc.).
5.12 General notes
Always use tools that are appropriate for the intended purpose.
Always replace the gaskets and/or the O-rings to ensure the hydraulic sealing remains intact
when replacing components. Only use genuine spare parts.
When installing spare parts make sure that:
•
the resistance element is properly housed, and the sealing gaskets are correctly installed.
•
the safety and regulation devices (thermostats) are properly installed inside their housings.
•
before reconnecting the equipment to the electrical supply, ensure tank is filled (referring to the
appropriate section) and check that there are no water leaks.
5.13 After-sale service
In case of errors or malfunctions, switch off the equipment and disconnect the power supply. Then
contact the technical support and the installer in the first instance.