14
6. TROUBLE SHOOTING
The solid waste refrigerators are designed and produced for a long life and trouble free
function. Alarm messages are displayed flashing and indicated by means of an acoustic
signal. To stop the alarm signal see page 11. Should nevertheless a malfunction occur, please
check as follow:
Trouble/Error message
Measures
Dark Display
•
Check electrical current supply (fuse, socket)
Alarm HI
Requested temperature is not
reached
•
Check set rated value
•
Doors closed properly?
•
Waste stored properly? (see chapter 4)
•
Defrost iced evaporator (remove waste containers
and switch off until evaporator is ice-free)
Alarm HO
Device too cold
•
Check set rated value
•
Switch off device, pull mains plug and switch on
again after approx. 2 minutes
Alarm E1
Room probe defective
•
Probe circuit broken
•
Probe circuit of controller not fixed
•
Probe defective
Alarm E2
Evaporator probe defective
•
Probe circuit broken
•
Fühlerleitung am Regler lose
•
Fühler defekt
Water in cold room
•
Check if device is placed on even ground
•
Clean defrost water tray and defrost water drain
•
Check inline of drain pipe
Please contact your nearest service station only after all the above is as it should be. In
case of claims, please state the model number and serial number mentioned on the
nameplate as well as the type of trouble.
You will find the wiring diagram in the switching cabinet (behind the machine- or installation
compartment door).
We pursue a continuous product improvement program. Technical and optical design
modifications are therefore subject to change without any prior notice.