Picture 1: Top view solid waste refrigerator, self-cooling, plug in
Electrical connection 230V
Cable length 2,30m
with shockproof plug
Initial operation / electrical connection of solid waste refrigerators Series AKO:
See hereto picture 2. Electrical connection has to be done over a correctly installed sealed
contact socket. We recommend a connection to a separate circuit (fuse 10A).
The further connections like condensate drain, refrigeration lines and control lines (on given
solenoid valve) have to be done by local refrigeration/electrical specialist.
Picture 2: Top view solid waste refrigerator, central cooling system
A = Electrical connection 230V
500mm FFL
B = Suction line
8mm
500mm FFL
C = Fluid pipeline
6mm
500mm FFL
D = Cooling system condensate
drainpipe. Connection to
funnel-shaped drain DN50,
50mm over FFL into existing
under floor siphons
Installation and connection instructions for the integrated evaporator system
Attention!
According to the norm DIN EN 378, integrated evaporator systems may only be tested or
operated on spot with maximum 24 bar working pressure (otherwise destruction of evaporator
could occur).
For different connection possibilities see below:
1.) Cooling only connection of
evaporator as diagram I
3
rd
pipe soldered up.
Attention!
Do not bend connection
pipes.
Diagram I
liquid
suction gas
160
A