ERROR
CODES
7
Error Codes
In the event of a possible malfunction, the unit will display an Error Code on the segmented display. Please
consult the following table when encountering an Error code.
Error Error Description
Potential Cause
Action Required
1
Broken Temperature Sensor E-01
Service required.
2
Broken Temperature Sensor E-02
Allow unit to cool for 30 minutes and try again.
If error persists, service is required.
3
Over Current (peak)
E-03
Verify electrical supply is within operating
parameters. Service may be required.
4
Overheat
E-04
Turn off. Let unit cool for 15 minutes. Make
sure the surrounding air temperature is below
115˚F/46˚C. Clean the air filter.
6
High Line Voltage
E-06
To reset, unplug the unit, wait 5 seconds, and
plug it in again. If the problem persists, have an
electrician monitor the line voltage.
7
Hardware Failure
E-07
Service required.
9
Hardware Failure
E-09
Service required.