10
IMPORTANT NOTE:
ALL inputs MUST be dry contact only! This
includes: alarm inputs, control inputs, sensing edges and sensing
devices. For any other devices not mentioned, please consult the
factory.
CONTROL STATION WIRING
Refer to Control Connection Diagrams on pages 11 and 28. Make
connection through hole labeled for control. Be sure to use the
control box opening with the 7/8" knockout for CONTROL cable(s).
All power wires use the 1-1/16" knockout. Do not run control
wires in the same conduit as power wires.
1. Complete electrical connections to the operator and the control
station. Fasten the control station to the wall and MOUNT THE
WARNING NOTICE BESIDE OR BELOW THE PUSH BUTTON
STATION.
2. Apply power to the operator. Press OPEN push button and
observe direction of door movement and then press the STOP
button.
If door did not move in the correct direction, check for
improper wiring at the control station or between operator and
control station.
If the operator is three phase and control station wiring is
correct, exchange any two of the three incoming power leads.
If electrical problems persist, see contact information on
page 18.
MOUNTING INSTRUCTIONS
1. Mount Control Stations no further than (12") from each other.
2. Mount Control Stations (12") from the door enclosure.
3. Mount WARNING NOTICE beside or below the Control Station.
N
E
P
O
E
S
O
L
C
P
O
T
S
W A R N I N G
OPEN
C O
L E
S
S T O P
TO PREVENT ENTRAPMENT DO
NOT START DOOR DOWNWARD
UNLESS DOORWAY IS CLEAR
WARNING
Keep Door in Sight at all Times When Door is Moving
Moving Door Can Cause
Serious Injury or Death
Keep Clear! Door May Move at any Time
Without Prior Warning
Do Not Let Children Operate the Door or Play
in the Door Area
C O N T R O L S T A T I O N W I R I N G A N D I N S T A L L A T I O N
To reduce the risk of SEVERE INJURY or DEATH:
• Install the control station where the door is visible, but away
from the door and its hardware. If control station CANNOT be
installed where door is visible, or if ANY device other than the
control station is used to activate the door, a reversing edge
MUST be installed on the bottom of the door. Failure to install
a reversing edge under these circumstances may result in
SERIOUS INJURY or DEATH to persons trapped beneath the
door.
• To avoid damage to door and operator, make ALL door locks
inoperative. Secure lock(s) in “open” position. If the door lock
needs to remain functional, install an interlock switch.
• Disconnect power at fuse box BEFORE proceeding.
• Service voltage MUST be run separately from class 2 circuits
(controls).
• ALL electrical connections MUST be made by a qualified
individual.
• DO NOT install ANY wiring or attempt to run the operator
without consulting the wiring diagram. It is required you install
a reversing edge BEFORE proceeding with the control station
installation. (Although suggested, optional in C2 mode)
Control Station
Push Buttons
WARNING Notice
N
E
P
O
E
S
O
L
C
P
O
T
S
W A R N I N G
OPEN
C O
L E
S
S T O P
TO PREVENT ENTRAPMENT DO
NOT START DOOR DOWNWARD
UNLESS DOORWAY IS CLEAR
WARNING
Keep Door in Sight at all Times When Door is Moving
Moving Door Can Cause
Serious Injury or Death
Keep Clear! Door May Move at any Time
Without Prior Warning
Do Not Let Children Operate the Door or Play
in the Door Area