LIMIT SWITCH ADJUSTMENT
MAKE SURE THE LIMIT NUTS ARE POSITIONED BETWEEN THE LIMIT SWITCH ACTUATORS
BEFORE PROCEEDING WITH ADJUSTMENTS. MAKE SURE OPENING AND THE AREA NEAR
DOOR/OPERATOR AND MECHANISMS ARE CLEAR OF OBSTRUCTIONS AND PERSONNEL.
1) To adjust limit nuts depress retaining plate to allow nut to spin freely. After adjustment,
ELECTRIC POWER BEFORE MANUALLY MOVING LIMIT NUTS.
TO AVOID SERIOUS PERSONAL INJURY OR DEATH FROM ELECTROCUTION, DISCONNECT
WARNING
release plate and ensure it seats fully in slots of both nuts.
2) To increase door travel, spin nut away from actuator. To decrease door travel, spin limit
nut toward actuator.
3) Adjust open limit nut so that door will stop in open position with the bottom of the door
even with top of door opening.
4) Repeat Steps 1 and 2 for close cycle. Adjust close limit nut so that actuator is engaged
as door fully seats at the floor.
6) Connect sensing edge to controller terminals 3 & 10 and test operation - if equipped.
CLOSE LIMIT SWITCH
OPEN LIMIT SWITCH
LIMIT NUTS
RETAINING
PLATE
7
5) Connect Photo Electric Sensors per the wiring diagram on page 10 and test operation.