6. If your pool is equipped with a heater or salt chlorinator, make sure the
bypass valves are set to the correct position as per the settings when your
pool was commissioned.
7. Observe your QuikClean system and note what it is doing. If you don’t feel
it is operating correctly, please refer to Figure 9 for helpful suggestions on
how to return your system to peak operating efficiency and effectiveness.
8. If you require additional support, please contact our support team via:
https://quikclean.com.au/service-support
Common symptoms, probable causes and solutions
Figure 9
identifies common symptoms and probable causes of performance
issues, and recommends solutions to optimise system performance.
Symptom
Probable Cause
Solution
Water Actuator
Valve does not
rotate.
Impeller is not
turning
Dirty filter and/or
baskets are full of debris.
Empty all baskets and clean filter.
Pause control is ON.
Ensure the pause control lever is in
the down position.
Return water is not properly
diverted to the QuikClean
system
Position valves on return manifold to
direct 100% of the water flow to the
QuikClean System.
Cleaning heads do
not come up all the
way.
Dirty filter and/or basket are
full of debris.
Empty all baskets and clean the filter.
Return water is not properly
diverted to the QuikClean
system.
Position valves on the return
manifold to direct 100% of the water
flow to the QuikClean System.
Cleaning head(s) will
not go down.
Debris is stuck in the head.
Remove cleaning head and flush it
with water, removing any debris that
may be lodged in the head. Check for
debris in the orifice and flow path.
QuikClean system
performance is not
the same as it was
when the pool was
first started up.
Dirty filter and/or basket are
full of debris.
Empty all baskets and clean the filter.
Debris is stuck in the head.
Remove the cleaning head and flush
it with water, removing any debris
that may be lodged in the head.
Check for debris in the orifice and
flow path.
Return water is not properly
diverted to the QuikClean
system.
Position valves on the return
manifold to direct 100% of the water
flow to the QuikClean system.
Page 8
FIGURE 9