19
In
more
detail...
GB
IE
CLGH3ASS Built-in Gas Hob
Gas connection
Regulation of burners
Caution
The regulation described can only be carried out with burners that use
methane gas and city gas (where available), whereas the screw must
be fully tightened in a clockwise direction on burners using liquid gas.
Regulation of the “MINIMUM” position on the burners.
To regulate the minimum position on the burners, follow the procedure below:
1. Turn on the burner and turn the knob to its MINIMUM position (small flame).
2. Remove the knob from the tap set for standard pressure. The knob is found
on the bar of the tap itself.
3. Place the tap bar on the work top, use a small screwdriver that fits the (gold)
screws located at the lower part of the tap and turn the fixing screw to the
right or left until the flame of the burner is regulated in the most suitable
manner to MINIMUM.
4. Make sure that the flame does not go out when changing the position quickly
from MAXIMUM to MINIMUM position.
5. The minimum flame height is 15mm.
Caution
End User should not adjust "Minimun" position on the burner by
themselves. It can only be adjusted be qualified technician according
to relative standard.
Technical and legal information
CLGH3ASS-C&L-A5-GB-IM-08.indd 19
10/18/13 11:30 AM