Electrical connection
All installation work must be carried out by a competent person or
qualified electrician.
Before connecting the mains supply, ensure that the mains voltage
corresponds to the voltage on the rating plate on the appliance.
Warning!
This appliance must be earthed.
Mains Supply could be connected to the Mains Voltage by Direct Connection.
USE A 13 AMP FUSE
DOUBLE POLE SWITCHED
FUSED SPUR OUTLET
FUSE ON
EUR
UK
Warning!
Make sure the fused spur outlet is located in an accessible position.
Direct Connection
•
If the appliance is being connected directly to the mains, an omnipolar circuit-breaker
must be installed with a minimum opening of 3 mm between contacts.
•
If the cable is damaged or to be replaced, the operation must be carried out by a
qualified electrician with dedicated tools to avoid any accidents.
•
The installer must ensure that the correct electrical connection has been made and
that it complies with wiring diagram.
•
The cable must not be bent or compressed.
•
The cable must be checked regularly and replaced by authorized technicians only.