5

MPA IO&M

B51223-005

*Intake Side Shown

•  1/2-13 x 1.00 Grade 5 Hex Head Cap Screw (or equivalent) 

4 required (1 in each corner) 

•  1/2 Flat Washer, 8 required (2 in each corner) 

•  1/2-13 Hex Nut (or equivalent), 4 required (1 in each 

corner). Recommended torque setting of 18 (ft-lb) 

•  Split Lock Washer (or equivalent), 4 required (1 in each 

corner).

A *Intake Side

A

B

 (Middle connections) 

*Intake Side Shown

•  Intake Side Panel Connection: A series of .22” diameter 

holes, 3” on center are provide to connect the front panel of 

the fan assembly to the customer’s equipment. The holes 

are sized for 1/4” sheet metal screws. 

•  All installation hardware supplied by end user.

B *Intake Side

B

Radial Gap, Overlap, and Impeller 

Alignment

Efficient fan performance can be maintained by having 

the correct gap and overlap between the impeller and inlet 

funnel. These items should be checked at installation, after 

the fan has been in operation for 24 hours, and after the unit 

has been serviced. 

Gap: distance between the OD of the funnel and the ID 

of the impeller concentricity. 
Overlap: distance the funnel and impeller overlap one 

another. 

This sketch shows both the gap and overlap dimensions for 

all sizes.

Gap

Overlap

Gap/Overlap Dimensions

Model

Minimum 

Overlap (in.)

Maximum 

Overlap (in.) Minimum Gap (in.)

100

0.12

0.29

0.06

120

0.12

0.32

0.07

135

0.12

0.35

0.07

150

0.19

0.41

0.09

165

0.25

0.47

0.11

180

0.31

0.50

0.11

195

0.38

0.57

0.12

225

0.44

0.63

0.14

245

0.50

0.69

0.17

270

0.56

0.76

0.20

300

0.62

0.88

0.24

330

0.75

0.96

0.26

365

0.81

1.13

0.27

402

0.88

1.23

0.31

Gap is adjusted by loosening the inlet funnel bolts and 

centering the funnel on the impeller. 

Electrical Interferences Hazard:

Motor Interferences Hazard:

Never loosen the motor attachment bolts to make adjustments to the 

impeller-to-funnel gap.

Overlap is adjusted by loosening the impeller hub from 

the shaft and moving the impeller to the desired position 

along the shaft. The transition between the inlet funnel and 

impeller should be as shown; there is a smooth feel to the 

profile when moving from one component to the other.

Содержание MPA Series

Страница 1: ...es not bind Compare all components with the bill of lading or packing list to verify that the proper unit was received Check each unit for any damage that may have occurred in transit Record on the De...

Страница 2: ...ained If units are to be stored outside they should be covered with a water resistant material Stored equipment should be on a clean dry floor or blocked up off the ground to prevent unit from setting...

Страница 3: ...ery dirty or high temperatures exist divide the service interval by 4 Lubrication requirements are normally attached to the motor Do not over lubricate The major cause of motor bearing failure is cont...

Страница 4: ...frequency controllers can generate motor noise Objects which are installed in a high velocity airstream can generate noise This includes flow sensors turning vanes etc Non uniform fan inlet condition...

Страница 5: ...nit has been serviced Gap distance between the OD of the funnel and the ID of the impeller concentricity Overlap distance the funnel and impeller overlap one another This sketch shows both the gap and...

Страница 6: ...s connected to the low pressure side see following diagram Measurement of Airflow Several factors affect the accuracy of this method of determining flow The equations below assume the following There...

Страница 7: ...7 MPA IO M B51223 005 Parts List Part No Description 1 Wheel 2 Inlet 3 Motor 1 3 2...

Страница 8: ...ces 2015 East Dale Street Springfield Missouri 65803 4637 explaining in writing in detail your complaint and referring to the specific model and serial numbers of your fan Upon receipt by Loren Cook C...

Отзывы: