          Version Number: 1.0 

 

Note: According to international standards, your monitor should be checked for accuracy every 
year. 

 

8. 

Certifications 

--------------------------------------------------------------------------------------------------------------- 

Device standard: 
This device is manufactured to meet the European blood pressure monitors: 
EN1060-1 / 1995 • EN1060-3 / 1997 • EN1060-4 / 2004 
Electromagnetic compatibility: 
Device fulfills the stipulations of the International standard 
IEC60601-1-2 

9. 

Technical Specifications 

------------------------------------------------------------------------------------------------------------------------- 
Model:B61T 

Wight:252g (unit net weight) 
Size: 121 (W) x 67 (L) x 30(H) mm 
Accessories: 1

×

Main Device, 1

×

Users manual, 1

×

Warranty card 

Operating Conditions: Temperature: 5

  to 40

; Humidity: 15% to 93% RH; Pressure altitude: 70KPa~ 

106Kpa  
Storage And Shipping Conditions:Temperature: -25

  to 70

; Humidity: 10% to 93% RH; Pressure altitude: 

70KPa~ 106Kpa 
Measuring method: Oscillometric 
Pressure sensor: Capacitive 

Measuring range: DIA: 40-130mmHg; SYS: 60-230mmHg 

Pulse: 40 to 199 per minute

 

Cuff pressure display range: 0–299 mmHg 
Memory: Automatically stores the last 99 measurements   
Measuring resolution: 1 mmHg 
Accuracy: Pressure within ± 3 mmHg / pulse ± 5 % of the reading 
Power source: Built-in Lithium Ion Polymer Battery 
Accessories: Wide range rigid cuff 8.7” – 14.2” (22 - 36 cm) 
Automatically power off : 120 seconds 
Users: Adult 
Expected service life of the device and accessories: 7 years 
Technical alterations reserved! 

 

ENVIRONMENTAL REQUIREMENTS 

 
OPERATING CONDITIONS 
Temperature: 5

  to 40

 

Humidity: 15% to 93% RH 
Pressure altitude: 70KPa~ 106Kpa

 

 
STORAGE AND SHIPPING CONDITIONS 
Temperature: -25

  to 70

 

Содержание B61T

Страница 1: ...ill prove helpful in allowing you to enjoy your measurement in hospitals and physician s offices throughout the world where accuracy and dependability are critical professional diagnostic products are...

Страница 2: ...using this device Blood pressure readings obtained by this device should be verified before prescribing or making adjustments to any medications used to control hypertension Under no circumstances sh...

Страница 3: ...e Warning This equipment shall not be serviced or maintained while in use with the patient Warning The patient is the intended operator the functions of monitoring blood pressure and pulse rate can be...

Страница 4: ...mHg while at rest In this case please consult your physician immediately Long term values at this level endanger your health due to continual damage to the blood vessels in your body If your systolic...

Страница 5: ...lerosis Furthermore the heart will become structurally damaged with increased blood pressure values 3 There are many different causes of high blood pressure We differentiate between the common primary...

Страница 6: ...high blood pressure 4 2 System Settings After the battery is fully recharged some functions can be set before use this monitor a Start Stop Press the Start Stop button one time The indicator around th...

Страница 7: ...measurement error of 10 mmHg Cuffs that are too narrow or too short result in false measurement values Selecting the correct cuff is extremely important Cuff size is dependent upon the circumference...

Страница 8: ...ed on the arm and connected to the blood pressure monitor the measurement can begin a Operate on the device Press the Stop Start button as the power on blue indictor is turned on The pump begins to in...

Страница 9: ...After the monitor has detected your blood pressure and pulse rate the cuff automatically deflates Your blood pressure will be voiced out or shown on the app on smart phone if operated by App 7 The mo...

Страница 10: ...ted with the Digital Blood Pressure Monitor B61T and its use Authorized Representative in the European Community CE Mark conforms to essential requirements of the Medical Device Directive 93 42 EEC Da...

Страница 11: ...sed by different patients wash hands before and after each use a Do not expose the device to either extreme temperatures humidity dust or direct sunlight b The cuff contains a sensitive air tight bubb...

Страница 12: ...e And Shipping Conditions Temperature 25 to 70 Humidity 10 to 93 RH Pressure altitude 70KPa 106Kpa Measuring method Oscillometric Pressure sensor Capacitive Measuring range DIA 40 130mmHg SYS 60 230mm...

Страница 13: ...ast 30 Electrical fast transient burst IEC 61000 4 4 2 kV for power supply lines 1 kV for input output lines 2 kV for power supply lines 1 kV for input output lines Mains power quality should be that...

Страница 14: ...netic field IEC 61000 4 8 3 A m 3 A m Power frequency magnetic fields should be at levels characteristic of a typical location in a typical commercial or hospital environment NOTE UT is the a c mains...

Страница 15: ...om fixed RF transmitters as determined by an electromagnetic site survey a should be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipment marked...

Страница 16: ...d Pressure Monitor B61T The Digital Blood Pressure Monitor B61T is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled The customer or the user of the M...

Страница 17: ...Version Number 1 0 10 Warranty Card...

Страница 18: ...n Jamr Medical Technology Co Ltd Address 2nd Floor A building No 2 Guiyuan Road Guihua Community Guanlan Town Longhua New District Shenzhen China Authorized Indian Representative Cooey Technologies Pv...

Отзывы: