          Version Number: 1.0 

 

                   

Fully Automatic Upper Arm       

 

                  Cooey Blood Pressure Monitor   

  Model Number: B61T   

                                          -------------------------------------------------------------------------- 

          USER’S MANUAL 

 

 

 
A Special Thank You... 

 

Thank you for choosing a blood pressure instrument. We're proud of the care and quality that goes into the 
manufacture of each and every item that bears our name. Only the finest materials are used to assure you of 
a timeless instrument designed for optimum performance. You'll quickly appreciate the results, for you now 
own one of the finest blood pressure instruments that money can buy. With proper care and maintenance, 
your automatic blood pressure monitor is sure to provide you with many years of dependable service. Please 
read the following instructions and general information which will prove helpful in allowing you to enjoy your 
measurement in hospitals and physician's offices throughout the world, where accuracy and dependability 
are critical, professional diagnostic products are the instruments of choice. 

 
Now you too can enjoy the benefits of engineering and quality at the comforts of your home. This feature 
rich instrument was designed to simplify the measurement of blood pressure and pulse rate at home and 
deliver consistent, dependable results. Your blood pressure monitor is a fully automatic digital blood pressure 
measuring device for use on the upper arm. It enables very fast and reliable measurement of the systolic and 
diastolic blood pressure as well as the pulse by way of the oscillometric method. This device offers clinically 
proven accuracy and has been designed to be user friendly. Read this booklet thoroughly before attempting 
to use your new Digital Blood Pressure Monitor. 

 

Содержание B61T

Страница 1: ...ill prove helpful in allowing you to enjoy your measurement in hospitals and physician s offices throughout the world where accuracy and dependability are critical professional diagnostic products are...

Страница 2: ...using this device Blood pressure readings obtained by this device should be verified before prescribing or making adjustments to any medications used to control hypertension Under no circumstances sh...

Страница 3: ...e Warning This equipment shall not be serviced or maintained while in use with the patient Warning The patient is the intended operator the functions of monitoring blood pressure and pulse rate can be...

Страница 4: ...mHg while at rest In this case please consult your physician immediately Long term values at this level endanger your health due to continual damage to the blood vessels in your body If your systolic...

Страница 5: ...lerosis Furthermore the heart will become structurally damaged with increased blood pressure values 3 There are many different causes of high blood pressure We differentiate between the common primary...

Страница 6: ...high blood pressure 4 2 System Settings After the battery is fully recharged some functions can be set before use this monitor a Start Stop Press the Start Stop button one time The indicator around th...

Страница 7: ...measurement error of 10 mmHg Cuffs that are too narrow or too short result in false measurement values Selecting the correct cuff is extremely important Cuff size is dependent upon the circumference...

Страница 8: ...ed on the arm and connected to the blood pressure monitor the measurement can begin a Operate on the device Press the Stop Start button as the power on blue indictor is turned on The pump begins to in...

Страница 9: ...After the monitor has detected your blood pressure and pulse rate the cuff automatically deflates Your blood pressure will be voiced out or shown on the app on smart phone if operated by App 7 The mo...

Страница 10: ...ted with the Digital Blood Pressure Monitor B61T and its use Authorized Representative in the European Community CE Mark conforms to essential requirements of the Medical Device Directive 93 42 EEC Da...

Страница 11: ...sed by different patients wash hands before and after each use a Do not expose the device to either extreme temperatures humidity dust or direct sunlight b The cuff contains a sensitive air tight bubb...

Страница 12: ...e And Shipping Conditions Temperature 25 to 70 Humidity 10 to 93 RH Pressure altitude 70KPa 106Kpa Measuring method Oscillometric Pressure sensor Capacitive Measuring range DIA 40 130mmHg SYS 60 230mm...

Страница 13: ...ast 30 Electrical fast transient burst IEC 61000 4 4 2 kV for power supply lines 1 kV for input output lines 2 kV for power supply lines 1 kV for input output lines Mains power quality should be that...

Страница 14: ...netic field IEC 61000 4 8 3 A m 3 A m Power frequency magnetic fields should be at levels characteristic of a typical location in a typical commercial or hospital environment NOTE UT is the a c mains...

Страница 15: ...om fixed RF transmitters as determined by an electromagnetic site survey a should be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipment marked...

Страница 16: ...d Pressure Monitor B61T The Digital Blood Pressure Monitor B61T is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled The customer or the user of the M...

Страница 17: ...Version Number 1 0 10 Warranty Card...

Страница 18: ...n Jamr Medical Technology Co Ltd Address 2nd Floor A building No 2 Guiyuan Road Guihua Community Guanlan Town Longhua New District Shenzhen China Authorized Indian Representative Cooey Technologies Pv...