4. Installation
MV3DB Series DB Units
ALSPA MV3000e Dynamic Braking Units
(07/06)
Page 4-14
9.
Mount the self-adhesive label in the “Options Fitted” area inside the Control door.
10.
Close and secure the Power door, close the Control door.
11.
External cables must be secured as close as possible to the drive.
4.3.5
Installation to Frame Size 6 Drives
Frame Size 6 Preparation
(Refer to Figure 4-9)
1.
Remove the M5 taptite screw (4) securing the blanking plate to the top of the drive
casing.
2.
Remove eight M5 taptite screws (5) securing the fan access plate (6) to the chassis and
remove the plate. Do not remove the fan securing screw .
3.
Slide the blanking plate (7) out of the drive and store.
4.
Remove two M10 nuts, spring washers and flat washers (10) securing the link (9) to the
DC+ and RECT+ studs. Remove the link.
5.
Remove the M10 hex head screw and washers (if fitted) from the top of the DC+ busbar
(2).
6.
Remove the M10 nut and washers from the DC– stud (3).
7.
Remove three M5 taptite screws (1) securing the transparent plastic shroud (8) to the
DC– busbar. Remove the shroud.