If the factory default of Zone 1 is desired to be changed (i.e. such that the entire keypad is a Zone 6 keypad for
instance), select the button whose number relates to the new desired zone (i.e. pick the button marked “6”) and
hold that button until you hear the first beep, then release. The keypad is now set to the new zone address such
that the operation of the 6 group buttons will be as follows: button marked “1” will be (Zone 6/Group1) sequencing
to the (Zone 6/Group 6) for the last button marked “6.”
Note
: if additional customization is required, you will need to use the e-Node Pilot application which permits
basically any type of additional customization to be performed.
Preset Buttons (top/bottom or combination of both).
The right pair of Preset Buttons activates one or more
connected motor controllers whose zone and/or group have been previously selected using the “Group/Zone
Selection” buttons to move motor(s) with matching address(es) to the selected preset. The top button directs the
specific controller to move to Preset 1, while the bottom button directs the controller to move to Preset 3. If both
buttons are depressed simultaneously, a command is generated that moves the controller to Preset 2
Specific Activity Buttons- Selected Zone/Group (UP/DOWN).
The pair of UP/DOWN buttons activates one or
connected motor controllers whose zone and/or group has been previously selected using the “Group/Zone
Selection” buttons
to
move motor(s) with matching address(es) in the selected direction. In the factory default
settings, if you tap the switch once in one of the applicable directions (UP or DOWN) and then release, the motor
controller will activate connected bi-directional motor(s) with matching addresses to travel in that appropriate
direction until the motor(s) reaches its desired (fully UP or fully DOWN) position.
Backlit LEDs.
To turn on the blue backlit LEDs on this keypad, hold the * button for one beep and then release. To
turn off the blue backlit LEDs, hold the * button for one beep and release.
* Button.
Selecting the * button before selecting either a (i) Specific Activity Button, or a (ii) Preset Button
directs the keypad to transmit an “All” command to all Group addresses currently configured within the keypad
plus
the Specific Activity Command or Preset Command selected.
In addition, additional features are available with * button. See table below.
Type of Operation
Details
UID Assignment Mode
Hold and quickly release * button within
100 ms (you should hear no beeps during
this period)
If in UID
assignment mode (by using e-Node and Pilot
application)
, hold and release * button within specific time and
keypad will be linked to the UID address (initially) broadcasted
onto bus.
Note:
After initial UID assignment has been made, either a
factory reset is required or the use of e-Node and e-Node Pilot
application is required
One beep mode
.
Hold and release * button after you hear
the first beep
This turns on the backlit LEDS. Alternatively, the next time this
sequence is received, the backlit LEDS with turn off if previously
on, or turn on if previously off.
Two beep mode
. Hold and release *
button after you hear the second beep
This is a CALIBRATE mode which sends the command
#1.1.0.MOTOR=CALIBRATE.
For more information See
Appendix 3 subtopic Auto Calibration
Note: this command should be used on motor assemblies that
have a door element. All motors should be send to home first
using individual controls for Motor A, Motor B (if present). Then
the Calibrate command should be invoked. This auto-calibrates
the IMC-300 MKII to know the location of all motors in their