Converging Systems Inc.
Page 10
Rev.5.0.0
c.
LV Connection
. Reserved for future. (Pins 1 on STI/LV connection block.
4
Programming Motor Addressing/Initial Setup
Background
:
The
IMC-x00x Controllers and their associated User Interface Control Devices (keypads)
have been designed with a rich feature set field proven in large commercial installations. A set of rich
software tools and programming aides have been designed for the trained installer to customize virtually
any feature within the IMC-300MKII-xx controller and connected User Interface Control Device(s).
When a Masking Director is initially set-up with one or more motors, specific motor settings (ccw, cw, etc.)
can be either configured through factory programmed DIP SWITCH settings or can be customized on the
factory floor. Should your installation only require such functionality, please proceed within this section.
However, if your installation requires additional customization not available with the information contained
within this section, please consult Converging Systems
Now follow the below steps:
4.1
Factory Programming-DIP Switch Programming
Certain often used templates have been re-programmed into the IMC-300MKII controller. These templates
can be automatically recalled by setting the on on-board PCB DIP switches to the positions documented in
. If a particular template is not re-loaded, then alternative programming is possible through the
use of e-Node Pilot. Refer to Section 5.2 below for more information here.
4.2
Customized Programming- (non-DIP SWITCH programming)
See Appendix 6 for more information.
5
Power On/Testing
IMPORTANT: MAKE SURE THAT THE AC POWER TO ALL CONTROLLERS IS TURNED OFF PRIOR
TO CONTINUING.
Directions
a.
Set the DIP Switches on the IMC-300MK-EM (and any connected IMC-300MKII-SL connected
versions) as per the directions in section 4 above.
b.
Make sure that you have connected all relevant motors for the DIP switch setting performed in Step
“a” above. In addition, for convenience, connect one Masking Director compatible keypad (BSKP-
2112 is the preferred keypad).
c.
For enhanced/accelerated testing, you may select to make a communication connection using
Ethernet connectivity.
d.
Power on all IMC-300MKII-xx Controllers by providing (compatible) AC power to all components.
See
e.
Verify each IMC-300x Controller has powered up properly by examining its status LED indicator.
Depending upon the configuration of each IMC-300x and its current operational status (whether or
not an operational IP connection is provided), a specific color and flash pattern for the on-board