20 cm
(8")
Any obstacle
ex: curtains
Floor
C
15 cm
(6")
B
2.5 cm
(1")
E
15 cm
(6")
B
75 cm
(30")
A
Minimum
clearances
In front
(A)
Sides
(B)
Above
(C)
Underneath
(E)
Recommended
height
7635-C10-BB
75 cm
(30 in)
15 cm
(6 in)
20 cm
(8 in)
2.5 cm
(1 in)
25 cm
(10 in)
7635-C15-BB
75 cm
(30 in)
15 cm
(6 in)
20 cm
(8 in)
2.5 cm
(1 in)
25 cm
(10 in)
HEATER INSTALLATION: This heater must be
installed in accordance with national and
local codes and CONVECTAIR recommends an
PUZ[HSSH[PVUI`HX\HSPȹLKLSLJ[YPJPHU
CAUTION: PLEASE MAINTAIN THE MINIMUM REQUIRED CLEARANCES (Fig. A).
CONVECTAIR RECOMMENDS AN INSTALLATION HEIGHT OF 25 CM (10").
These instructions have been established at the moment of the heater’s
manufacturing and in conformity with the standardization at that moment.
!
Fig. A
Volume
0
Volume
1
Hors volume
Outside volume
0,5 m
1' 8"
0,5 m
1' 8"
2,25 m * - 7' 5" *
Volume
2
Ύ,ĂƵƚĞƵƌăƉĂƌƟƌĚƵĨŽŶĚĚĞůĂďĂŝŐŶŽŝƌĞ͘
,ĞŝŐŚƚĨƌŽŵƚŚĞďŽƩŽŵŽĨƚŚĞďĂƚŚ͘
Fig. A2
13.
Minimum installation
KPZ[HUJLZ[V[OLȺVVY
walls, furniture, etc., must
be respected.
-PNf(
. If
the device is installed in a
bathroom or powder room
(Fig. A2)
, it must be installed
V\[ZPKLVM]VS\TLfH[H
TPUPT\TKPZ[HUJLVMfT
from the bathtub and/or
ZOV^LYHUKT\Z[ILȹ[[LK
^P[OHJSHZZ(KPȸLYLU[PHS
circuit breaker.
(IMPORTANT: See applicable
national and local codes)
.