6.
1. Connect the ground wire (C) to the
green wire (G) inside the connection
box.
2. Connect the black (B) and red (R) leads
from the heater to the electrical supply
wires (see diagram).
3. Carefully put back all wires inside the
box, close and screw the cover.
CONVECTAIR recommends that this heater be installed by a qualified
electrician in accordance with national and local codes.
A rectangular junction box must be installed in the wall, prior to
electrical hookup. The box must be of appropriate size to receive
the necessary electrical connections and the 2-3/4" x 4-1/2"
(70mm x 115mm) cover that is supplied with the unit cable.
CAUTION: This unit must be connected to a 240 volts or 208 volts circuit,
60 cycles. Cut off the power in the electrical panel before making
wiring connections to prevent electrical shock or equipment damage.
Canada
B- Black
G - Green
R - Red
C - Copper
R
R
HEA
TER
B
B
G
PO
WER LINE
C
2 ELECTRICAL CONNECTION
4. Hook the heater onto the mounting bracket tabs with the unit slightly
angled towards you. Push the heater towards the wall until it is engaged
on both locking tabs.