6
®
7
SEELEY INTERNATIONAL
–
OWNER
’
S MANUAL
MAINTENANCE
M3000 Coolmaster Portable Evaporative Cooler
Cleaning
The exterior surfaces can be wiped with a
damp cloth and a little household detergent.
Do not use abrasive cleaners and solvents
(Fig 15).
To drain water
Place a bucket under the cooler and drain
the water from the reservoir through the drain
plug hole (refer Fig 1 part C).
Unplug the cooler from the power
supply before servicing.
At least once per year at the end of summer
it is advisable to perform some
simple cleaning on your cooler to maintain its
high efficiency. This involves cleaning the
water system and Aspen filter pad.
Top panel removal (cleaning inside of
unit)
To gain access to the unit for cleaning
remove the top panel by carefully releasing
the 4 catches located inside the top.
Using a small screwdriver, push the clips in
about 3mm (Fig 16) and at the same time
push the panel upwards.
I L L 2 3 5 - A
1
16
I L L 2 3 2 - B
14
15
I L L 2 3 3 - B
L
J
K
15
Cleaning inside of unit
Wash the Aspen pad with water; replace if
worn or deteriorated.
Clean the pump strainer (Fig 19) by removing
dirt and rubbish. Clean the inside of the
reservoir.
Spreader pad removal
Remove the Aspen pad assembly (J, K & L)
by lifting it upwards. Disconnect the water
hose from the spreader (L) before removing
the Aspen pad assembly completely.
Internal view (fig 17,18 & 19 )
J
Aspen cooling pad
K
Wire mesh support
L
Spreader
N
Water Strainer
I L L 2 3 4 - A
1
K
L
J
16
14
17
18
I L L 2 3 7 - A
N
19
MAINTENANCE cont.