background image

Starting the air conditioner

Step 1:

Ensure the cooler is plugged in

and switched on.

Step 2:

Step 3:

Heat mode

Cooling mode

Fan mode

Step 4:

!

Step 5:

Press the ON/OFF button on the

remote control or ON/OFF

button on the

control panel to start the air conditioner.

Press the MODE button

o n

the control panel or remote control to
select the desired operating mode (Fig. 7
&11):

- reverse cycle

heating (CM15RCS only)

- refrigerated

cooling

- Fan only operation

(no cooling)

Press

/

on the control panel

or on the remote control to select the
desired operating ‘set’ temperature.

In Cooling mode, cooling will occur if the
set temperature is less than the room
temperature.
In Heating mode, heating will occur if the
set temperature is greater than the room
temperature.

Do not set the cooling temperature too

low. This will consume more power. 24°C
is the recommended set temperature, with
high fan speed.

Changing the set temperature will

have no effect in FAN mode.

Press the FAN SPEED button

on the control panel or remote control to
adjust the fan speed. Each press will cycle
the fan speed through low, medium & high.

In Cooling & Heating modes, the fan

will continue to run even when the
compressor has cycled off.

r s

The set temperature range is 16°C-31°C

Tip

Note!

Note!

Important!

During heating mode the unit

may enter a defrost cycle.

When this

occurs, the compressor will stop and the
fan will continue to run. This is a normal
function for all reverse cycle air
conditioners. The compressor will re-start
and normal heating operation will
recommence

when the defrost cycle is

complete.
During cooling and heating mode, water
will collect in the air conditioner’s tank. In
cooling mode this water is recirculated and
some will be exhausted out with the hot air,
but will slowly fill up the tank. This occurs
more quickly in humid conditions. There is
no recirculation in heating mode.

If the

tank should fill, the ‘water full’

symbol

will flash on the control display, the unit will
‘beep’ 15 times and then shut down. The
cooler cannot be restarted until the water
tank is drained. Refer to the Maintenance
section for draining the tank should this
occur.

Step.2

Step.8

Step.3

Step.5

Step.4

Step.7

Step.6

OPERATION

7

11

Содержание ClimateMaster CM15RCS

Страница 1: ...Instruction Manual ClimateMaster CM15RW CM15RCS ClimateMaster Portable Refrigerated Air Conditioner ...

Страница 2: ...ucts must not be disposed of with household waste This product should be taken to your local recycling centre for safe treatment Please read these instructions prior to using the appliance and save them for future reference ...

Страница 3: ...r their safety Children should be supervised to ensure that they do not play with the appliance Do not place anything through the ventilating slots Your Convair cooler is a portable air conditioning unit that supplies refrigerated air to a personal area within a room It is not intended to function as a house or room air conditioner Be sure the appliance has been securely and correctly installed ac...

Страница 4: ...fety cont Caution before connecting the electrical power cord to a power outlet check that the air conditioner voltage is the same as your power supply refer to the rating label located on the back of the unit Ensure the power supply is correctly earthed and rated Plug the air conditioner directly into a properly installed power outlet Never use an extension cord double adaptor or multi power outl...

Страница 5: ...anel Air Filter Drain Air Intake active carbon filter to be fitted here Air Intake side panel Air Intake side panel Power Cord Exhaust Air Outlet Exhaust Hose Active Carbon Filter Window Attachment Exhaust Fitting window end Rating Label Cord Storage Door COMPONENT LOCATION 3 ...

Страница 6: ...ed The window attachment can be installed horizontally or vertically depending on the window type Note Note The minimum distance required from the operating air conditioner to any obstructing objects or walls is 50cm Fig 6 Keep the exhaust hose as short and straight as possible and minimise kinks This will maximise the cooling performance Don t use extension pieces for the exhaust pipe as this wil...

Страница 7: ...p mode Press to turn the air conditioner on and off Press to cycle from Heat CM15RCS only Cooling and Fan only modes Press to increase to decrease the set temperature r s To avoid damage to the control panel do not operate with sharp objects NOTE 7 CONTROL PANEL 5 DISPLAY PANEL Ion Tio2 Heating Mode Indicator only for CM15RCS Cooling Mode Indicator Fan Mode Indicator Sleep Mode Indicator Timer Ind...

Страница 8: ... battery cover and insert new batteries Remove the batteries and replace with new ones If this does not solve the problem contact your nearest service centre for advice AAA making sure the and are matching the compartment markings Fig 10 If the remote control will not operate the air conditioner the batteries may need to be replaced The air conditioner must be plugged in and switched on for the re...

Страница 9: ... remote control to adjust the fan speed Each press will cycle the fan speed through low medium high In Cooling Heating modes the fan will continue to run even when the compressor has cycled off r s The set temperature range is 16 C 31 C Tip Note Note Important During heating mode the unit may enter a defrost cycle When this occurs the compressor will stop and the fan will continue to run This is a...

Страница 10: ...n TiO button on the control panel or remote control to activate this feature The air conditioner is fitted with a timer function This can be set up to 24 hours in advance To use this function the cooler must be plugged in and ready to operate With the air conditioner ON press the TIMER button on the remote control or control panel The control panel display will flash and show the time setting Pres...

Страница 11: ... soft damp cloth to wipe the body clean Never use aggressive chemicals spirits detergents chemically treated cloths or other cleansing solutions These substances could possibly damage the cabinet Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt and then rinse under running water no hotter than 40 C Dry thoroughly before replacing Take care to replace the filters back in...

Страница 12: ...air needs to be completely removed from the room The air conditioner is not as cool as it once was Are the filters dusty or dirty restricting the airflow Is the air inlet or outlet blocked Is the room temperature below the set temperature The air conditioner is too noisy Is the air conditioner positioned unevenly so as to create vibration Is the floor beneath the air conditioner uneven It is possi...

Страница 13: ...tion Cooling Capacity Watts Heating Capacity Watts Dehumidifying Capacity L hr Air Flow Volume m hr 3 Noise Level Sound Pressure dB A Power Supply Input Power Watts Fuse Type Refrigerant Type Charge kg High Side Pressure Maximum MPa Low Side Pressure Maximum MPa Water Ingress Protection Rating Weight kg Dimensions mm width depth height Based on manufacturer s test results using the Air Enthalpy me...

Страница 14: ...NOTES 12 ...

Страница 15: ......

Страница 16: ...e policy of Seeley International to introduce continual product improvement Accordingly specifications are subject to change without notice Please consult with your dealer to confirm the specifications of the model selected 00237832 D seeleyinternational com AU 1112 ...

Отзывы: