Contura C620T Style Скачать руководство пользователя страница 4

GB

22

EU Declaration of Conformity

Manufacturer

NIBE AB / Contura

Address

Box 134, Skulptörvägen 10
285 23 Markaryd, Sweden

E-Mail

[email protected]

Website

www.contura.eu

Telephone

+46 433 275100

THIS DECLARATION OF CONFORMITY IS ISSUED UNDER OUR SOLE RESPONSIBILITY FOR THE FOLLOWING PRODUCT:

Trade name

Contura 600 Style-series 610 (A) / 620 (T) / 690 (A/T)

Identification of product 

www.contura.eu

THE OBJECT OF THE DECLARATION DESCRIBED ABOVE IS IN CONFORMITY WITH -
THE RELEVANT UNION HARMONIZATION LEGISLATION:

THE RELEVANT HARMONIZED STANDARDS:

DIR 2009/125/EC

EN 13240:2001/A2:2004/AC:2007

REG (EU) 2015/1185

CEN/TS 15883:2010

REG (EU) 2015/1186
REG (EU) 2017/1369
REG (EU) 305/2011

TECHNICAL DOCUMENTATION

Indirect heating functionality: 

No

Direct heat output:

6,0 kW

Energy Efficiency Index (EEI):

114,7

Test report

RRF 40 17 4615, NB 1625

CHARACTERISTICS WHEN OPERATING WITH THE PREFERRED FUEL
ITEM

SYMBOL

VALUE

UNIT

ITEM

SYMBOL

VALUE

UNIT

HEAT OUTPUT

USEFUL EFFICIENCY, BASED ON NET CALORIFIC VALUE (NCV )

Nominal heat output:

P

nom

6,0

kW

Useful efficiency at nominal 
heat output

η  

th,nom

86,0

%

AUXILIARY ELECTRICITY CONSUMPTION

TYPE OF HEAT OUTPUT/ROOM TEMPERATURE CONTROL

At nominal heat output

el

max

-

kW

Single stage heat output, no room temperature control

Yes

At minimum heat output

el

min

-

kW

Two or more manual stages, no room temperature control

No

In standby mode

el

SB

-

kW

With mechanic thermostat room temperature control

No

With electronic room temperature control

No

With electronic room temperature control plus day timer

No

With electronic room temperature control plus week timer

No

OTHER CONTROL OPTIONS

Room temperature control, with presence detection

No

Room temperature control, with open window detection

No

With distance control option

Specific precautions for assembly, 
installation, or maintenance.

Fire protection and safety distances to combustible building materials must be observed under all circumstances.
A sufficient supply of combustion air must always be guaranteed. Air suction systems can interfere with the combustion 
air supply.

FUEL

PREFERRED 

FUEL  

OTHER SUITABLE 

FUEL

η 

S

   (%)

EMISSIONS AT NOMINAL HEAT OUTPUT

PM

OGC

CO

NO

x

mg/ Nm

3

 (13% O

2

)

Wood logs with moisture content ≤25%

Yes

No

76,0

<40

<120

<1500

<200

Compressed wood with moisture content <12%

No

Yes

76,0

<40

<120

<1500

<200

Other woody biomass

No

No

Non-wood biomass

No

No

Anthracite and dry steam coal

No

No

Hard coke

No

No

Low temperature coke

No

No

Bituminous coal

No

No

Lignite briquettes

No

No

Peat briquettes

No

No

Blended fossil fuel briquettes

No

No

Other fossil fuel

No

No

Blended biomass and fossil fuel briquettes

No

No

Other blend of biomass and solid fuel

No

No

The undersigned is responsible for the manufacture and conformity with the declared performance.

Niklas Gunnarsson,

 Business area manager NIBE STOVES 

Markaryd, January 1, 2022

Содержание C620T Style

Страница 1: ...ve becomes very hot During operation certain surfaces of the stove become very hot and can cause burn injury if touched Be aware of the strong heat radiated through the hatch glass Placing flammable material closer than the safe distance indicated may cause a fire Pyre lighting can cause quick gas ignition with the risk of damage to property and personal injury Connection to chimney The stove must...

Страница 2: ...rom floor to lower edge of hatch A separate glass hearth plate accessory increases the connection height to the chimney by 10 mm Permitted area for combustible parts of the building If the stove is placed on a hearth plate made of glass for example accessory the height from the floor is affected by a distance corresponding to the thickness of the hearth plate for a free standing glass hearth plate...

Страница 3: ...e safety Pass Fire classification A1 Minimum distance to flammable materials Rear 100 mm Side 507 mm Ceiling 810 mm Front 1200 mm Floor 0 mm Corner 100 mm Fire hazard due to burning fuel falling out Pass EN 13240 2001 A2 2004 AC 2007 Cleanability Pass Emissions from combustion CO 0 08 Surface temperatures Pass Temperature on the handle Pass Mechanical resistance Pass Temperature in the space for w...

Страница 4: ...s no room temperature control No In standby mode elSB kW With mechanic thermostat room temperature control No With electronic room temperature control No With electronic room temperature control plus day timer No With electronic room temperature control plus week timer No OTHER CONTROL OPTIONS Room temperature control with presence detection No Room temperature control with open window detection N...

Отзывы: