Contura C620T Style Скачать руководство пользователя страница 2

GB

20

!

The minimum distance in front of 
the stove opening to combustible 
parts of the building or interior 
decoration must be at least 1,2 m.

The dimension diagrams only 
show the minimum permitted 
installation distances for the 
stove. When connecting to a steel 
flue, also note the safety distance 
requirements of the flue. The 
safety distance between an un-
insulated flue and a combustible 
part of the building should be at 
least 450 mm.

Installation distances 

WHEN INSTALLING TURNTABLE (OPTION) 

the follow-

ing installation distances do not apply. 
See the separate turntable installation instructions.

A =  height from floor to chimney 

connection upwards

B =  height from floor to c/c chimney 

connection rear

C = height from floor to air inlet
D = height from floor to lower edge 

of hatch

A separate glass hearth 
plate (accessory) 
increases the connection 
height to the chimney by 
10 mm.

Permitted area for 

combustible parts 

of the building

*    If the stove is placed on a hearth plate made of glass for example (accessory), the height from the floor is affected by a distance corresponding to the thickness of the hearth plate, for a free standing  
 

glass hearth plate this is 10 mm.

**  To prevent discolouration of painted non-flammable walls we recommend that the same side distance as to combustible walls is used.

INSTALLATION AGAINST COMBUSTIBLE WALLS

INSTALLATION AGAINST FIREWALLS

1290

580

2100*

D 367

92

219

Combustible roof

140

110

B 1078*

A 1205*

C 389

40

515

Air inlet Ø67

Ø150

848

685

335

100

Combustible wall

650

780

636

285

50

650

Fire-retardant wall
of brick or concrete

1100

520

192

50

227**

900

Fire-retardant wall
of brick or concrete

800

507

570

570

242

100

Combustible wall

C620T / C620TG Style

Содержание C620T Style

Страница 1: ...ve becomes very hot During operation certain surfaces of the stove become very hot and can cause burn injury if touched Be aware of the strong heat radiated through the hatch glass Placing flammable material closer than the safe distance indicated may cause a fire Pyre lighting can cause quick gas ignition with the risk of damage to property and personal injury Connection to chimney The stove must...

Страница 2: ...rom floor to lower edge of hatch A separate glass hearth plate accessory increases the connection height to the chimney by 10 mm Permitted area for combustible parts of the building If the stove is placed on a hearth plate made of glass for example accessory the height from the floor is affected by a distance corresponding to the thickness of the hearth plate for a free standing glass hearth plate...

Страница 3: ...e safety Pass Fire classification A1 Minimum distance to flammable materials Rear 100 mm Side 507 mm Ceiling 810 mm Front 1200 mm Floor 0 mm Corner 100 mm Fire hazard due to burning fuel falling out Pass EN 13240 2001 A2 2004 AC 2007 Cleanability Pass Emissions from combustion CO 0 08 Surface temperatures Pass Temperature on the handle Pass Mechanical resistance Pass Temperature in the space for w...

Страница 4: ...s no room temperature control No In standby mode elSB kW With mechanic thermostat room temperature control No With electronic room temperature control No With electronic room temperature control plus day timer No With electronic room temperature control plus week timer No OTHER CONTROL OPTIONS Room temperature control with presence detection No Room temperature control with open window detection N...