C 850

www.contura.eu

Installation 

Instructions

Содержание C 850

Страница 1: ...C 850 www contura eu Installation Instructions ...

Страница 2: ...ECLARED PERFORMANCE Essential characteristics Performance Harmonised technical specification Reaction to fire A1 WT Minimum distance to combustible material 100 mm to rear 500 mm to side Other safety distances according to the installation instructions Risk of falling embers Approved Emissions from combustion CO 0 07 NOx 98 mg m3 OGC 51 mg m3 PM 20 mg m3 Surface temperatures Approved Cleaning opti...

Страница 3: ...a family We hope you will get a great deal of pleasure from your new stove As a new owner of a Contura stove you have secured a product with timeless design and long service life Contura also has combustion that is both environmentally friendly and efficient for the best heat production Read through these installation instructions carefully before installation Read how to best light your stove in ...

Страница 4: ...bout how the stoves must be assembled and installed To ensure the function and safety of the stove we recommend that the installation is carried out by an authorised technician Contact one of our dealers who can recommend suitable technicians Building application These main instructions may give guidance which would contravene national building regulations Please refer to supplementary instruction...

Страница 5: ...N Prior to installation If the insert needs to be put down to be moved loose components should be removed This is described at the end of these installation instructions 1 Fire bars 2 Grate disc 3 Fire bricks 4 Type plate 5 Hot air grate ...

Страница 6: ...0 mm The stove requires a draft in the chimney of at least 12 Pa The draft is affected both by the length and area of the chimney and by how well sealed it is Minimum recommended chimney length is 3 5 m and suitable cross section area is 150 200 cm 140 160 mm in diameter A flue with sharp bends and horizontal routing reduces the draught in the chimney Maximum horizontal flue is 1 m on the conditio...

Страница 7: ...ust be selected In hot areas the duct should be insulated with 30 mm mineral wool covered with a moisture inhibitor plastic It is important that the lead in between the pipe and the wall or floor is sealed using jointing compound A 1 m length of condensation insulated ducting for combustion air is available as an accessory Through the external wall Indirect air supply through the external wall Thr...

Страница 8: ... flue also note the safety distance requirements of the flue The safety distance between an un insulated flue and a combustible part of the building should be at least 450 mm Installation distances WHEN INSTALLING TURNTABLE OPTION the fol lowing installation distances do not apply See the separate turntable installation instructions A height from floor to chimney connection upwards B height from f...

Страница 9: ...EMBLY Installing C 850 Final inspection of the installation It is extremely important that the installation is inspected by an authorised chimney sweep before the stove is used Also read the Lighting instructions before lighting for the first time ...

Страница 10: ...EMOVAL How to remove the fire bricks Handle the vermiculite with care Lift the smoke baffle with one hand whilst removing the sides The side posts need not be removed when sweeping Reinstall in reverse order Removal ...