C 660K
72
GB
800
500
250
100
100
200
300
400
195
295
395
495
Combustible wall
800
500*
200
50
Fire-retardant wall of
brick or concrete
635
300
50
780
Fire-retardant wall of
brick or concrete
325
75
660
810
Combustible wall
D 300
E 1000
B 1000
A 1130
C 340
470
100
510
40
Ø150
Air inlet Ø64
1220
2100
295
590
Combustible roof
Air inlet Ø64
* If the stove is placed on a hearth plate made of glass for example (accessory), the height from the floor is affected by a distance corresponding to the thickness of the hearth plate. Also applies to
separate
glass hearth plates (accessory).
** To prevent discolouration of painted non-flammable walls we recommend that the same side distance as to combustible walls is used.
The minimum distance in front of
the stove opening to combustible
parts of the building or interior
decoration must be at least 1 m.
When top connecting a steel flue,
please refer to the particular
manufacturer's installation
instructions. Observe the safety
distance to combustible material
required by the steel flue
Installation distances
WHEN INSTALLING TURNTABLE (OPTION)
the
following installation distances do not apply.
See the separate turntable installation instruc-
tions.
A = height from floor to chimney
connection upwards
B = height from floor to c/c chimney
connection rear
C = height from floor to air inlet
D = height from floor to lower edge
of hatch
E = height from floor to upper edge
of hatch
Permitted
area for
combustible
material
A separate glass hearth
plate (accessory)
increases the connection
height to the chimney
by 10 mm. The spacers
supplied with the hearth
plate are installed on the
stove before connection.
INSTALLATION DISTANCES